VMXi : a fully automated, fully remote, high-flux in situ macromolecular crystallography beamline

open access.

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 26(2019), Pt 1 vom: 01. Jan., Seite 291-301
1. Verfasser: Sanchez-Weatherby, Juan (VerfasserIn)
Weitere Verfasser: Sandy, James, Mikolajek, Halina, Lobley, Carina M C, Mazzorana, Marco, Kelly, Jon, Preece, Geoff, Littlewood, Rich, Sørensen, Thomas L M
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2019
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article automated beamline operation in situ diffraction experiments room-temperature data collection serial crystallography
LEADER 01000caa a22002652 4500
001 NLM292833164
003 DE-627
005 20250224164220.0
007 cr uuu---uuuuu
008 231225s2019 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577518015114  |2 doi 
028 5 2 |a pubmed25n0975.xml 
035 |a (DE-627)NLM292833164 
035 |a (NLM)30655497 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Sanchez-Weatherby, Juan  |e verfasserin  |4 aut 
245 1 0 |a VMXi  |b a fully automated, fully remote, high-flux in situ macromolecular crystallography beamline 
264 1 |c 2019 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 30.01.2019 
500 |a Date Revised 07.06.2024 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a open access. 
520 |a VMXi is a new high-flux microfocus macromolecular crystallography beamline at Diamond Light Source. The beamline, dedicated to fully automated and fully remote data collection of macromolecular crystals in situ, allows rapid screening of hundreds of crystallization plates from multiple user groups. Its main purpose is to give fast feedback at the complex stages of crystallization and crystal optimization, but it also enables data collection of small and delicate samples that are particularly difficult to harvest using conventional cryo-methods, crystals grown in the lipidic cubic phase, and allows for multi-crystal data collections in drug discovery programs. The beamline is equipped with two monochromators: one with a narrow band-pass and fine energy resolution (optimal for regular oscillation experiments), and one with a wide band-pass and a high photon flux (optimal for fast screening). The beamline has a state-of-the-art detector and custom goniometry that allows fast data collection. This paper describes the beamline design, current status and future plans 
650 4 |a Journal Article 
650 4 |a automated beamline operation 
650 4 |a in situ diffraction experiments 
650 4 |a room-temperature data collection 
650 4 |a serial crystallography 
700 1 |a Sandy, James  |e verfasserin  |4 aut 
700 1 |a Mikolajek, Halina  |e verfasserin  |4 aut 
700 1 |a Lobley, Carina M C  |e verfasserin  |4 aut 
700 1 |a Mazzorana, Marco  |e verfasserin  |4 aut 
700 1 |a Kelly, Jon  |e verfasserin  |4 aut 
700 1 |a Preece, Geoff  |e verfasserin  |4 aut 
700 1 |a Littlewood, Rich  |e verfasserin  |4 aut 
700 1 |a Sørensen, Thomas L M  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 26(2019), Pt 1 vom: 01. Jan., Seite 291-301  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:26  |g year:2019  |g number:Pt 1  |g day:01  |g month:01  |g pages:291-301 
856 4 0 |u http://dx.doi.org/10.1107/S1600577518015114  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 26  |j 2019  |e Pt 1  |b 01  |c 01  |h 291-301