Motion Artifacts and Correction in Multipulse High-Frame Rate Contrast-Enhanced Ultrasound

High-frame-rate (HFR) ultrasound (US) imaging and contrast-enhanced US (CEUS) are often implemented using multipulse transmissions, to enhance image quality. Multipulse approaches, however, suffer from degradation in the presence of motion, especially when coherent compounding and CEUS are combined....

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 66(2019), 2 vom: 04. Feb., Seite 417-420
1. Verfasser: Stanziola, A (VerfasserIn)
Weitere Verfasser: Toulemonde, M, Li, Y, Papadopoulou, V, Corbett, R, Duncan, N, Eckersley, R J, Tang, M X
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2019
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article Research Support, Non-U.S. Gov't
LEADER 01000naa a22002652 4500
001 NLM292011202
003 DE-627
005 20231225072135.0
007 cr uuu---uuuuu
008 231225s2019 xx |||||o 00| ||eng c
024 7 |a 10.1109/TUFFC.2018.2887164  |2 doi 
028 5 2 |a pubmed24n0973.xml 
035 |a (DE-627)NLM292011202 
035 |a (NLM)30571621 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Stanziola, A  |e verfasserin  |4 aut 
245 1 0 |a Motion Artifacts and Correction in Multipulse High-Frame Rate Contrast-Enhanced Ultrasound 
264 1 |c 2019 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 06.10.2021 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a High-frame-rate (HFR) ultrasound (US) imaging and contrast-enhanced US (CEUS) are often implemented using multipulse transmissions, to enhance image quality. Multipulse approaches, however, suffer from degradation in the presence of motion, especially when coherent compounding and CEUS are combined. In this paper, we investigate this effect on the intensity of HFR CEUS in deep tissue imaging using simulations and in vivo contrast echocardiography (CE). The simulation results show that the motion artifact is much higher when the flow is in an axial direction than a lateral direction. Using a pulse repetition frequency suitable for cardiac imaging, a motion of 35 cm/s can cause as much as 28.5 dB decrease in image intensity, where compounding can contribute up to 18.7 dB of intensity decrease (11 angles). These motion effects are also demonstrated for in vivo cardiac HFR CE, where the large velocities of both the myocardium and the blood are present. Intensity reductions of 10.4 dB are readily visible in the chamber. Finally, we demonstrate how performing motion-correction before pulse inversion compounding greatly reduces such motion artifact and improve image signal-to-noise ratio and contrast 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Toulemonde, M  |e verfasserin  |4 aut 
700 1 |a Li, Y  |e verfasserin  |4 aut 
700 1 |a Papadopoulou, V  |e verfasserin  |4 aut 
700 1 |a Corbett, R  |e verfasserin  |4 aut 
700 1 |a Duncan, N  |e verfasserin  |4 aut 
700 1 |a Eckersley, R J  |e verfasserin  |4 aut 
700 1 |a Tang, M X  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 66(2019), 2 vom: 04. Feb., Seite 417-420  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:66  |g year:2019  |g number:2  |g day:04  |g month:02  |g pages:417-420 
856 4 0 |u http://dx.doi.org/10.1109/TUFFC.2018.2887164  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 66  |j 2019  |e 2  |b 04  |c 02  |h 417-420