Simultaneous Axial Multifocal Imaging Using a Single Acoustical Transmission : A Practical Implementation

Standard ultrasound imaging techniques rely on sweeping a focused beam across a field of view; however, outside the transmission focal depth, image resolution and contrast are degraded. High-quality deep tissue in vivo imaging requires focusing the emitted field at multiple depths, yielding high-res...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 66(2019), 2 vom: 06. Feb., Seite 273-284
1. Verfasser: Ilovitsh, Asaf (VerfasserIn)
Weitere Verfasser: Ilovitsh, Tali, Foiret, Josquin, Stephens, Douglas N, Ferrara, Katherine W
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2019
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article Research Support, N.I.H., Extramural
LEADER 01000caa a22002652 4500
001 NLM291606202
003 DE-627
005 20250224120848.0
007 cr uuu---uuuuu
008 231225s2019 xx |||||o 00| ||eng c
024 7 |a 10.1109/TUFFC.2018.2885080  |2 doi 
028 5 2 |a pubmed25n0971.xml 
035 |a (DE-627)NLM291606202 
035 |a (NLM)30530361 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Ilovitsh, Asaf  |e verfasserin  |4 aut 
245 1 0 |a Simultaneous Axial Multifocal Imaging Using a Single Acoustical Transmission  |b A Practical Implementation 
264 1 |c 2019 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 03.02.2020 
500 |a Date Revised 14.07.2024 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a Standard ultrasound imaging techniques rely on sweeping a focused beam across a field of view; however, outside the transmission focal depth, image resolution and contrast are degraded. High-quality deep tissue in vivo imaging requires focusing the emitted field at multiple depths, yielding high-resolution and high-contrast ultrasound images but at the expense of a loss in frame rate. Recent developments in ultrasound technologies have led to user-programmable systems, which enable real-time dynamic control over the phase and apodization of each individual element in the imaging array. In this paper, we present a practical implementation of a method to achieve simultaneous axial multifoci using a single acoustical transmission. Our practical approach relies on the superposition of axial multifoci waveforms in a single transmission. The delay in transmission between different elements is set such that pulses constructively interfere at multiple focal depths. The proposed method achieves lateral resolution similar to successive focusing, but with an enhanced frame rate. The proposed method uses standard dynamic receive beamforming, identical to two-way focusing, and does not require additional postprocessing. Thus, the method can be implemented in real time on programmable ultrasound systems that allow different excitation signals for each element. The proposed method is described analytically and validated by laboratory experiments in phantoms and ex vivo biological samples 
650 4 |a Journal Article 
650 4 |a Research Support, N.I.H., Extramural 
700 1 |a Ilovitsh, Tali  |e verfasserin  |4 aut 
700 1 |a Foiret, Josquin  |e verfasserin  |4 aut 
700 1 |a Stephens, Douglas N  |e verfasserin  |4 aut 
700 1 |a Ferrara, Katherine W  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 66(2019), 2 vom: 06. Feb., Seite 273-284  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:66  |g year:2019  |g number:2  |g day:06  |g month:02  |g pages:273-284 