Laser-heating system for high-pressure X-ray diffraction at the Extreme Conditions beamline I15 at Diamond Light Source

open access.

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 25(2018), Pt 6 vom: 01. Nov., Seite 1860-1868
1. Verfasser: Anzellini, Simone (VerfasserIn)
Weitere Verfasser: Kleppe, Annette K, Daisenberger, Dominik, Wharmby, Michael T, Giampaoli, Ruggero, Boccato, Silvia, Baron, Marzena A, Miozzi, Francesca, Keeble, Dean S, Ross, Allan, Gurney, Stuart, Thompson, Jon, Knap, Giles, Booth, Mark, Hudson, Lee, Hawkins, Dave, Walter, Michael J, Wilhelm, Heribert
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2018
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Diamond Light Source X-ray diffraction high pressure and temperature laser-heated diamond anvil cell
LEADER 01000naa a22002652 4500
001 NLM29039984X
003 DE-627
005 20231225064639.0
007 cr uuu---uuuuu
008 231225s2018 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577518013383  |2 doi 
028 5 2 |a pubmed24n0967.xml 
035 |a (DE-627)NLM29039984X 
035 |a (NLM)30407199 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Anzellini, Simone  |e verfasserin  |4 aut 
245 1 0 |a Laser-heating system for high-pressure X-ray diffraction at the Extreme Conditions beamline I15 at Diamond Light Source 
264 1 |c 2018 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 09.11.2018 
500 |a Date Revised 04.10.2023 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a open access. 
520 |a In this article, the specification and application of the new double-sided YAG laser-heating system built on beamline I15 at Diamond Light Source are presented. This system, combined with diamond anvil cell and X-ray diffraction techniques, allows in situ and ex situ characterization of material properties at extremes of pressure and temperature. In order to demonstrate the reliability and stability of this experimental setup over a wide range of pressure and temperature, a case study was performed and the phase diagram of lead was investigated up to 80 GPa and 3300 K. The obtained results agree with previously published experimental and theoretical data, underlining the quality and reliability of the installed setup 
650 4 |a Journal Article 
650 4 |a Diamond Light Source 
650 4 |a X-ray diffraction 
650 4 |a high pressure and temperature 
650 4 |a laser-heated diamond anvil cell 
700 1 |a Kleppe, Annette K  |e verfasserin  |4 aut 
700 1 |a Daisenberger, Dominik  |e verfasserin  |4 aut 
700 1 |a Wharmby, Michael T  |e verfasserin  |4 aut 
700 1 |a Giampaoli, Ruggero  |e verfasserin  |4 aut 
700 1 |a Boccato, Silvia  |e verfasserin  |4 aut 
700 1 |a Baron, Marzena A  |e verfasserin  |4 aut 
700 1 |a Miozzi, Francesca  |e verfasserin  |4 aut 
700 1 |a Keeble, Dean S  |e verfasserin  |4 aut 
700 1 |a Ross, Allan  |e verfasserin  |4 aut 
700 1 |a Gurney, Stuart  |e verfasserin  |4 aut 
700 1 |a Thompson, Jon  |e verfasserin  |4 aut 
700 1 |a Knap, Giles  |e verfasserin  |4 aut 
700 1 |a Booth, Mark  |e verfasserin  |4 aut 
700 1 |a Hudson, Lee  |e verfasserin  |4 aut 
700 1 |a Hawkins, Dave  |e verfasserin  |4 aut 
700 1 |a Walter, Michael J  |e verfasserin  |4 aut 
700 1 |a Wilhelm, Heribert  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 25(2018), Pt 6 vom: 01. Nov., Seite 1860-1868  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:25  |g year:2018  |g number:Pt 6  |g day:01  |g month:11  |g pages:1860-1868 
856 4 0 |u http://dx.doi.org/10.1107/S1600577518013383  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 25  |j 2018  |e Pt 6  |b 01  |c 11  |h 1860-1868