|
|
|
|
LEADER |
01000naa a22002652 4500 |
001 |
NLM290399718 |
003 |
DE-627 |
005 |
20231225064639.0 |
007 |
cr uuu---uuuuu |
008 |
231225s2018 xx |||||o 00| ||eng c |
024 |
7 |
|
|a 10.1107/S1600577518013899
|2 doi
|
028 |
5 |
2 |
|a pubmed24n0967.xml
|
035 |
|
|
|a (DE-627)NLM290399718
|
035 |
|
|
|a (NLM)30407186
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Zinn, T
|e verfasserin
|4 aut
|
245 |
1 |
0 |
|a Ultra-small-angle X-ray photon correlation spectroscopy using the Eiger detector
|
264 |
|
1 |
|c 2018
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
500 |
|
|
|a Date Completed 09.11.2018
|
500 |
|
|
|a Date Revised 07.12.2018
|
500 |
|
|
|a published: Print-Electronic
|
500 |
|
|
|a Citation Status PubMed-not-MEDLINE
|
520 |
|
|
|a open access.
|
520 |
|
|
|a Successful implementation of the single-photon-counting Eiger 500k pixel array detector for sub-millisecond X-ray photon correlation spectroscopy (XPCS) measurements in the ultra-small-angle scattering region is reported. The performance is demonstrated by measuring the dynamics of dilute silica colloids in aqueous solvents when the detector is operated at different counter depths, 4, 8 and 12 bit. In the fastest mode involving 4 bit parallel readout, a stable frame rate of 22 kHz is obtained that enabled measurement of intensity-intensity autocorrelation functions with good statistics down to the 50 µs range for a sample with sufficient scattering power. The high frame rate and spatial resolution together with large number of pixels of the detector facilitate the investigation of sub-millisecond dynamics over a broad length scale by multispeckle XPCS. This is illustrated by an example involving phoretic motion of colloids during the phase separation of the solvent
|
650 |
|
4 |
|a Journal Article
|
650 |
|
4 |
|a USAXS
|
650 |
|
4 |
|a XPCS
|
650 |
|
4 |
|a coherent X-ray scattering
|
650 |
|
4 |
|a colloid dynamics
|
700 |
1 |
|
|a Homs, A
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Sharpnack, L
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Tinti, G
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Fröjdh, E
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Douissard, P A
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Kocsis, M
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Möller, J
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Chushkin, Y
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Narayanan, T
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Journal of synchrotron radiation
|d 1994
|g 25(2018), Pt 6 vom: 01. Nov., Seite 1753-1759
|w (DE-627)NLM09824129X
|x 1600-5775
|7 nnns
|
773 |
1 |
8 |
|g volume:25
|g year:2018
|g number:Pt 6
|g day:01
|g month:11
|g pages:1753-1759
|
856 |
4 |
0 |
|u http://dx.doi.org/10.1107/S1600577518013899
|3 Volltext
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_40
|
912 |
|
|
|a GBV_ILN_350
|
912 |
|
|
|a GBV_ILN_2005
|
951 |
|
|
|a AR
|
952 |
|
|
|d 25
|j 2018
|e Pt 6
|b 01
|c 11
|h 1753-1759
|