Ultralow-temperature device dedicated to soft X-ray magnetic circular dichroism experiments

open access.

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 25(2018), Pt 6 vom: 01. Nov., Seite 1727-1735
1. Verfasser: Kappler, J P (VerfasserIn)
Weitere Verfasser: Otero, E, Li, W, Joly, L, Schmerber, G, Muller, B, Scheurer, F, Leduc, F, Gobaut, B, Poggini, L, Serrano, G, Choueikani, F, Lhotel, E, Cornia, A, Sessoli, R, Mannini, M, Arrio, M A, Sainctavit, Ph, Ohresser, P
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2018
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article XMCD magnetism soft X-rays ultralow-temperature
LEADER 01000caa a22002652 4500
001 NLM290399688
003 DE-627
005 20240716231932.0
007 cr uuu---uuuuu
008 231225s2018 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577518012717  |2 doi 
028 5 2 |a pubmed24n1472.xml 
035 |a (DE-627)NLM290399688 
035 |a (NLM)30407183 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Kappler, J P  |e verfasserin  |4 aut 
245 1 0 |a Ultralow-temperature device dedicated to soft X-ray magnetic circular dichroism experiments 
264 1 |c 2018 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 09.11.2018 
500 |a Date Revised 16.07.2024 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a open access. 
520 |a A new ultralow-temperature setup dedicated to soft X-ray absorption spectroscopy and X-ray magnetic circular dichroism (XMCD) experiments is described. Two experiments, performed on the DEIMOS beamline (SOLEIL synchrotron), demonstrate the outstanding performance of this new platform in terms of the lowest achievable temperature under X-ray irradiation (T = 220 mK), the precision in controlling the temperature during measurements as well as the speed of the cooling-down and warming-up procedures. Moreover, owing to the new design of the setup, the eddy-current power is strongly reduced, allowing fast scanning of the magnetic field in XMCD experiments; these performances lead to a powerful device for X-ray spectroscopies on synchrotron-radiation beamlines facilities 
650 4 |a Journal Article 
650 4 |a XMCD 
650 4 |a magnetism 
650 4 |a soft X-rays 
650 4 |a ultralow-temperature 
700 1 |a Otero, E  |e verfasserin  |4 aut 
700 1 |a Li, W  |e verfasserin  |4 aut 
700 1 |a Joly, L  |e verfasserin  |4 aut 
700 1 |a Schmerber, G  |e verfasserin  |4 aut 
700 1 |a Muller, B  |e verfasserin  |4 aut 
700 1 |a Scheurer, F  |e verfasserin  |4 aut 
700 1 |a Leduc, F  |e verfasserin  |4 aut 
700 1 |a Gobaut, B  |e verfasserin  |4 aut 
700 1 |a Poggini, L  |e verfasserin  |4 aut 
700 1 |a Serrano, G  |e verfasserin  |4 aut 
700 1 |a Choueikani, F  |e verfasserin  |4 aut 
700 1 |a Lhotel, E  |e verfasserin  |4 aut 
700 1 |a Cornia, A  |e verfasserin  |4 aut 
700 1 |a Sessoli, R  |e verfasserin  |4 aut 
700 1 |a Mannini, M  |e verfasserin  |4 aut 
700 1 |a Arrio, M A  |e verfasserin  |4 aut 
700 1 |a Sainctavit, Ph  |e verfasserin  |4 aut 
700 1 |a Ohresser, P  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 25(2018), Pt 6 vom: 01. Nov., Seite 1727-1735  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:25  |g year:2018  |g number:Pt 6  |g day:01  |g month:11  |g pages:1727-1735 
856 4 0 |u http://dx.doi.org/10.1107/S1600577518012717  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 25  |j 2018  |e Pt 6  |b 01  |c 11  |h 1727-1735