Flexible sample cell for real-time GISAXS, GIWAXS and XRR : design and construction

Since the properties of functional materials are highly dependent on their specific structure, and since the structural changes, for example during crystallization, induced by coating and annealing processes are significant, the study of structure and its formation is of interest for fundamental and...

Description complète

Détails bibliographiques
Publié dans:Journal of synchrotron radiation. - 1994. - 25(2018), Pt 6 vom: 01. Nov., Seite 1664-1672
Auteur principal: Berlinghof, M (Auteur)
Autres auteurs: Bär, C, Haas, D, Bertram, F, Langner, S, Osvet, A, Chumakov, A, Will, J, Schindler, T, Zech, T, Brabec, C J, Unruh, T
Format: Article en ligne
Langue:English
Publié: 2018
Accès à la collection:Journal of synchrotron radiation
Sujets:Journal Article GISAXS GIWAXS XRR in situ thin film
LEADER 01000caa a22002652 4500
001 NLM290399610
003 DE-627
005 20250224083421.0
007 cr uuu---uuuuu
008 231225s2018 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577518013218  |2 doi 
028 5 2 |a pubmed25n0967.xml 
035 |a (DE-627)NLM290399610 
035 |a (NLM)30407176 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Berlinghof, M  |e verfasserin  |4 aut 
245 1 0 |a Flexible sample cell for real-time GISAXS, GIWAXS and XRR  |b design and construction 
264 1 |c 2018 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 09.11.2018 
500 |a Date Revised 09.11.2018 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Since the properties of functional materials are highly dependent on their specific structure, and since the structural changes, for example during crystallization, induced by coating and annealing processes are significant, the study of structure and its formation is of interest for fundamental and applied science. However, structure analysis is often limited to ex situ determination of final states due to the lack of specialized sample cells that enable real-time investigations. The lack of such cells is mainly due to their fairly complex design and geometrical restrictions defined by the beamline setups. To overcome this obstacle, an advanced sample cell has been designed and constructed; it combines automated doctor blading, solvent vapor annealing and sample hydration with real-time grazing-incidence wide- and small-angle scattering (GIWAXS/GISAXS) and X-ray reflectivity (XRR). The sample cell has limited spatial requirements and is therefore widely usable at beamlines and laboratory-scale instruments. The cell is fully automatized and remains portable, including the necessary electronics. In addition, the cell can be used by interested scientists in cooperation with the Institute for Crystallography and Structural Physics and is expandable with regard to optical secondary probes. Exemplary research studies are presented, in the form of coating of P3HT:PC61PM thin films, solvent vapor annealing of DRCN5T:PC71BM thin films, and hydration of supported phospholipid multilayers, to demonstrate the capabilities of the in situ cell 
650 4 |a Journal Article 
650 4 |a GISAXS 
650 4 |a GIWAXS 
650 4 |a XRR 
650 4 |a in situ 
650 4 |a thin film 
700 1 |a Bär, C  |e verfasserin  |4 aut 
700 1 |a Haas, D  |e verfasserin  |4 aut 
700 1 |a Bertram, F  |e verfasserin  |4 aut 
700 1 |a Langner, S  |e verfasserin  |4 aut 
700 1 |a Osvet, A  |e verfasserin  |4 aut 
700 1 |a Chumakov, A  |e verfasserin  |4 aut 
700 1 |a Will, J  |e verfasserin  |4 aut 
700 1 |a Schindler, T  |e verfasserin  |4 aut 
700 1 |a Zech, T  |e verfasserin  |4 aut 
700 1 |a Brabec, C J  |e verfasserin  |4 aut 
700 1 |a Unruh, T  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 25(2018), Pt 6 vom: 01. Nov., Seite 1664-1672  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:25  |g year:2018  |g number:Pt 6  |g day:01  |g month:11  |g pages:1664-1672 
856 4 0 |u http://dx.doi.org/10.1107/S1600577518013218  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 25  |j 2018  |e Pt 6  |b 01  |c 11  |h 1664-1672