Monitoring daily routine performance in quantitative NMR (qNMR) spectroscopy : Is the system suitability test necessary?

© 2018 John Wiley & Sons, Ltd.

Bibliographische Detailangaben
Veröffentlicht in:Magnetic resonance in chemistry : MRC. - 1985. - (2018) vom: 02. Okt.
1. Verfasser: Monakhova, Yulia B (VerfasserIn)
Weitere Verfasser: Diehl, Bernd W K
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2018
Zugriff auf das übergeordnete Werk:Magnetic resonance in chemistry : MRC
Schlagworte:Journal Article NMR automation quantification system suitability test
LEADER 01000caa a22002652 4500
001 NLM289128978
003 DE-627
005 20240229161956.0
007 cr uuu---uuuuu
008 231225s2018 xx |||||o 00| ||eng c
024 7 |a 10.1002/mrc.4798  |2 doi 
028 5 2 |a pubmed24n1308.xml 
035 |a (DE-627)NLM289128978 
035 |a (NLM)30277277 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Monakhova, Yulia B  |e verfasserin  |4 aut 
245 1 0 |a Monitoring daily routine performance in quantitative NMR (qNMR) spectroscopy  |b Is the system suitability test necessary? 
264 1 |c 2018 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 27.02.2024 
500 |a published: Print-Electronic 
500 |a Citation Status Publisher 
520 |a © 2018 John Wiley & Sons, Ltd. 
520 |a Nuclear magnetic resonance spectrometry (NMR) finds numerous applications in pharmacy, cosmetic, and food control as well as in developing tools for "big data" analysis. However, there remains a need for automated tools to assess instrument system suitability in real time for each particular routine sample. An automated procedure has been introduced to monitor a number of characteristics (resolution, symmetry, and half width) in real time after the measurement of two samples distributed by the vendor (0.3% CHCl3 in acetone-d6 with tetramethylsilane and 2 mM sucrose in H2 O-D2 O). The results over 11 months were discussed in terms of average values, standard deviations, and spectrometer variability. Moreover, multivariate statistical procedure was implemented to evaluate metrics generated from three NMR spectrometers. Performance of three NMR spectrometers (500 MHz with BBO Prodigy Cryoprobe, 500 MHz with BBFOPLUS SmartProbe, and 600 MHz with BBO Cryoprobe) differed significantly. The developed routine was also applied to calculate the performance characteristics during routine quantitative NMR experiments. The procedure was evaluated for NMR spectra of 659 active pharmaceutical ingredients dissolved in CDCl3 , DMSO, and CH3 OD. This test is more preferable than the routine procedure using standard solutions because the performance is estimated separately for each matrix at the specific time point of measurements. Our automated routine is the ideal tool for any NMR laboratory. In full automation, the NMR data are validated directly for each sample, making unnecessary daily measurements of standard solutions and manual evaluation to their NMR spectra 
650 4 |a Journal Article 
650 4 |a NMR 
650 4 |a automation 
650 4 |a quantification 
650 4 |a system suitability test 
700 1 |a Diehl, Bernd W K  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Magnetic resonance in chemistry : MRC  |d 1985  |g (2018) vom: 02. Okt.  |w (DE-627)NLM098179667  |x 1097-458X  |7 nnns 
773 1 8 |g year:2018  |g day:02  |g month:10 
856 4 0 |u http://dx.doi.org/10.1002/mrc.4798  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |j 2018  |b 02  |c 10