Development of a KNN Ceramic-Based Lead-Free Linear Array Ultrasonic Transducer

High-frequency array transducers can provide higher imaging resolution than traditional transducers, thus resolving smaller features and producing finer images. Commercially available ultrasonic transducers are mostly made with lead-based piezoelectric materials, which are harmful to the environment...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 65(2018), 11 vom: 05. Nov., Seite 2113-2120
1. Verfasser: Zhang, Zhiqiang (VerfasserIn)
Weitere Verfasser: Chen, Ruimin, Wang, Bo, Zhang, Tianfu, Su, Min, Liu, Rong, Yang, Jiaxing, Cao, Xiaodong, Li, Yongxiang, Zheng, Hairong, Shung, K Kirk, Humayun, Mark S, Zhou, Qifa, Qiu, Weibao
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2018
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article Research Support, N.I.H., Extramural Research Support, Non-U.S. Gov't
Beschreibung
Zusammenfassung:High-frequency array transducers can provide higher imaging resolution than traditional transducers, thus resolving smaller features and producing finer images. Commercially available ultrasonic transducers are mostly made with lead-based piezoelectric materials, which are harmful to the environment and public health. This paper presents the development of the 64-elements high-frequency (18.3 MHz) lead-free linear array ultrasonic transducer based on (K0.44Na0.52Li0.04)(Nb0.86Ta0.1Sb0.04)O3 (KNLNTS) piezoceramic. Array elements were spaced at a 75- pitch, and interconnected via a custom flexible circuit. The two matching layers and a light backing material were used to improve the performance of the array. The developed KNLNTS ceramic-based lead-free linear array exhibited a center frequency of 18.3 MHz, an average -6-dB bandwidth of 42%, an average two-way insertion loss of 41.8 dB, and a crosstalk between the adjacent elements of less than -53 dB near the center frequency. An image of a tungsten wire phantom was acquired using a Verasonics Vantage research ultrasound system. Results from imaging tests demonstrated a good imaging capability with a spatial resolution of axially and laterally, indicating that the lead-free linear array ultrasonic transducer based on KNLNTS ceramics is a promising alternative to lead-based transducers for ultrasound medical imaging
Beschreibung:Date Completed 30.09.2019
Date Revised 30.09.2019
published: Print-Electronic
Citation Status MEDLINE
ISSN:1525-8955
DOI:10.1109/TUFFC.2018.2868413