Quantitative Assessment of the Effect of the Out-of-Plane Movement of the Homogenous Ellipsoidal Model of the Left Ventricle on the Deformation Measures Estimated Using 2-D Speckle Tracking-An In-Silico Study

Effect of the out-of-plane (OOP) movement amplitude on estimates of global displacements (radial, circumferential) and strains (radial , circumferential ) was studied in an ellipsoidal model of the left ventricle using finite-element modeling (FEM), synthetic ultrasonic data, and short-axis view. Th...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 65(2018), 10 vom: 16. Okt., Seite 1789-1803
1. Verfasser: Zmigrodzki, Jakub (VerfasserIn)
Weitere Verfasser: Cygan, Szymon, Wilczewska, Aleksandra, Kaluzynski, Krzysztof
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2018
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article Research Support, Non-U.S. Gov't
LEADER 01000naa a22002652 4500
001 NLM286514613
003 DE-627
005 20231225051907.0
007 cr uuu---uuuuu
008 231225s2018 xx |||||o 00| ||eng c
024 7 |a 10.1109/TUFFC.2018.2856127  |2 doi 
028 5 2 |a pubmed24n0955.xml 
035 |a (DE-627)NLM286514613 
035 |a (NLM)30010558 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Zmigrodzki, Jakub  |e verfasserin  |4 aut 
245 1 0 |a Quantitative Assessment of the Effect of the Out-of-Plane Movement of the Homogenous Ellipsoidal Model of the Left Ventricle on the Deformation Measures Estimated Using 2-D Speckle Tracking-An In-Silico Study 
264 1 |c 2018 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 20.11.2019 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Effect of the out-of-plane (OOP) movement amplitude on estimates of global displacements (radial, circumferential) and strains (radial , circumferential ) was studied in an ellipsoidal model of the left ventricle using finite-element modeling (FEM), synthetic ultrasonic data, and short-axis view. This effect was assessed using median of the absolute relative error (RE) of the global parameters. FEM provided node displacements for synthetic ultrasonic data and reference data generation. Displacements were estimated using block-matching (BM) and B-spline (BS) methods. FEM-derived data analysis, free from errors resulting from speckle tracking, indicated that the tissue motion introduced REs of global strain estimates below 4.5%. The effect of the OOP motion amplitude on strain estimates was strain specific and depended on the displacement estimation method. In the case of , the increase of the OOP amplitude resulted in quasi-linear increase of the RE from approximately 10% to 15%. The modulus of the end-systolic (ES) errors of the estimates almost linearly increased with increasing OOP amplitude approximately from 10% to 16%. REs of the estimate were close to 80% and 40%, respectively, in the case of the BM and BS methods, and increased with increasing OOP amplitude. The modulus of the ES errors of the estimates in the case of the BS method was about -40% and showed low sensitivity to the OOP amplitude; in the BM case, these errors varied approximately from -70% to -58% for OOP amplitude from 0 to 15 mm 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Cygan, Szymon  |e verfasserin  |4 aut 
700 1 |a Wilczewska, Aleksandra  |e verfasserin  |4 aut 
700 1 |a Kaluzynski, Krzysztof  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 65(2018), 10 vom: 16. Okt., Seite 1789-1803  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:65  |g year:2018  |g number:10  |g day:16  |g month:10  |g pages:1789-1803 
856 4 0 |u http://dx.doi.org/10.1109/TUFFC.2018.2856127  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 65  |j 2018  |e 10  |b 16  |c 10  |h 1789-1803