Optimization of ozonation and peroxone process for simultaneous control of micropollutants and bromate in wastewater

The study aims to simultaneously control micropollutants and bromate formations by using ozonation and peroxone process. The batch experiments were run with variations in specific ozone dose (SOD) and hydrogen peroxide-to-ozone (H2O2/O3) ratio. Based on the removal by ozonation and peroxone, micropo...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Water science and technology : a journal of the International Association on Water Pollution Research. - 1986. - 2017(2018), 2 vom: 31. Mai, Seite 404-411
1. Verfasser: Phattarapattamawong, Songkeart (VerfasserIn)
Weitere Verfasser: Kaiser, Andreas Marius, Saracevic, Ernis, Schaar, Heidemarie Paula, Krampe, Jörg
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2018
Zugriff auf das übergeordnete Werk:Water science and technology : a journal of the International Association on Water Pollution Research
Schlagworte:Journal Article Bromates Sulfuric Acids Waste Water Water Pollutants, Chemical Ozone 66H7ZZK23N Hydrogen Peroxide BBX060AN9V potassium peroxymonosulfuric acid HL6A2XXU5D