A sagittally confined high-resolution spectrometer in the `water window'

open access.

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 25(2018), Pt 3 vom: 01. Mai, Seite 738-747
1. Verfasser: Li, Zhuo (VerfasserIn)
Weitere Verfasser: Li, Bin
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2018
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article X-ray spectrometers diffraction principle geometric optics optical aberration analysis and optimization ray tracing water window
LEADER 01000caa a22002652 4500
001 NLM283615265
003 DE-627
005 20250223122115.0
007 cr uuu---uuuuu
008 231225s2018 xx |||||o 00| ||eng c
024 7 |a 10.1107/S160057751800468X  |2 doi 
028 5 2 |a pubmed25n0945.xml 
035 |a (DE-627)NLM283615265 
035 |a (NLM)29714183 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Li, Zhuo  |e verfasserin  |4 aut 
245 1 2 |a A sagittally confined high-resolution spectrometer in the `water window' 
264 1 |c 2018 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 12.11.2023 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a open access. 
520 |a The authors report a novel scheme for a grazing-incidence spectrometer forming an excellent meridional flat field in its detector domain to deliver the desired spectral resolution throughout the full designated spectral range, while reducing the sagittal astigmatism substantially to enhance the spectral intensity. The optical properties of the system are thoroughly investigated and optimized, and the detector plane is fitted well to the meridional or sagittal focal curves. The authors demonstrated that a resolving power of 6000-18000 could be achieved within the `water window' (2-5 nm) for an effective meridional source size of 200 µm (r.m.s.), and it would be further improved to 20000-40000 if the source size was confined to 50 µm (r.m.s.) 
650 4 |a Journal Article 
650 4 |a X-ray spectrometers 
650 4 |a diffraction principle 
650 4 |a geometric optics 
650 4 |a optical aberration analysis and optimization 
650 4 |a ray tracing 
650 4 |a water window 
700 1 |a Li, Bin  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 25(2018), Pt 3 vom: 01. Mai, Seite 738-747  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:25  |g year:2018  |g number:Pt 3  |g day:01  |g month:05  |g pages:738-747 
856 4 0 |u http://dx.doi.org/10.1107/S160057751800468X  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 25  |j 2018  |e Pt 3  |b 01  |c 05  |h 738-747