Magic angle spinning NMR with metallized rotors as cylindrical microwave resonators

Copyright © 2018 John Wiley & Sons, Ltd.

Bibliographische Detailangaben
Veröffentlicht in:Magnetic resonance in chemistry : MRC. - 1985. - 56(2018), 9 vom: 19. Sept., Seite 831-835
1. Verfasser: Scott, Faith J (VerfasserIn)
Weitere Verfasser: Sesti, Erika L, Choi, Eric J, Laut, Alexander J, Sirigiri, Jagadishwar R, Barnes, Alexander B
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2018
Zugriff auf das übergeordnete Werk:Magnetic resonance in chemistry : MRC
Schlagworte:Journal Article Research Support, N.I.H., Extramural Research Support, U.S. Gov't, Non-P.H.S. dynamic nuclear polarization electron decoupling magic angle spinning pulsed DNP solid state NMR time domain DNP Coated Materials, Biocompatible mehr... Sodium Acetate 4550K0SC9B Copper 789U1901C5
LEADER 01000naa a22002652 4500
001 NLM283209763
003 DE-627
005 20231225040008.0
007 cr uuu---uuuuu
008 231225s2018 xx |||||o 00| ||eng c
024 7 |a 10.1002/mrc.4744  |2 doi 
028 5 2 |a pubmed24n0944.xml 
035 |a (DE-627)NLM283209763 
035 |a (NLM)29672916 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Scott, Faith J  |e verfasserin  |4 aut 
245 1 0 |a Magic angle spinning NMR with metallized rotors as cylindrical microwave resonators 
264 1 |c 2018 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 29.08.2019 
500 |a Date Revised 29.08.2019 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a Copyright © 2018 John Wiley & Sons, Ltd. 
520 |a We introduce a novel design for millimeter wave electromagnetic structures within magic angle spinning (MAS) rotors. In this demonstration, a copper coating is vacuum deposited onto the outside surface of a sapphire rotor at a thickness of 50 nm. This thickness is sufficient to reflect 197-GHz microwaves, yet not too thick as to interfere with radiofrequency fields at 300 MHz or prevent sample spinning due to eddy currents. Electromagnetic simulations of an idealized rotor geometry show a microwave quality factor of 148. MAS experiments with sample rotation frequencies of ωr /2π = 5.4 kHz demonstrate that the drag force due to eddy currents within the copper does not prevent sample spinning. Spectra of sodium acetate show resolved 13 C J-couplings of 60 Hz and no appreciable broadening between coated and uncoated sapphire rotors, demonstrating that the copper coating does not prevent shimming and high-resolution nuclear magnetic resonance spectroscopy. Additionally, 13 C Rabi nutation curves of ω1 /2π = 103 kHz for both coated and uncoated rotors indicate no detrimental impact of the copper coating on radio frequency coupling of the nuclear spins to the sample coil. We present this metal coated rotor as a first step towards an MAS resonator. MAS resonators are expected to have a significant impact on developments in electron decoupling, pulsed dynamic nuclear polarization (DNP), room temperature DNP, DNP with low-power microwave sources, and electron paramagnetic resonance detection 
650 4 |a Journal Article 
650 4 |a Research Support, N.I.H., Extramural 
650 4 |a Research Support, U.S. Gov't, Non-P.H.S. 
650 4 |a dynamic nuclear polarization 
650 4 |a electron decoupling 
650 4 |a magic angle spinning 
650 4 |a pulsed DNP 
650 4 |a solid state NMR 
650 4 |a time domain DNP 
650 7 |a Coated Materials, Biocompatible  |2 NLM 
650 7 |a Sodium Acetate  |2 NLM 
650 7 |a 4550K0SC9B  |2 NLM 
650 7 |a Copper  |2 NLM 
650 7 |a 789U1901C5  |2 NLM 
700 1 |a Sesti, Erika L  |e verfasserin  |4 aut 
700 1 |a Choi, Eric J  |e verfasserin  |4 aut 
700 1 |a Laut, Alexander J  |e verfasserin  |4 aut 
700 1 |a Sirigiri, Jagadishwar R  |e verfasserin  |4 aut 
700 1 |a Barnes, Alexander B  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Magnetic resonance in chemistry : MRC  |d 1985  |g 56(2018), 9 vom: 19. Sept., Seite 831-835  |w (DE-627)NLM098179667  |x 1097-458X  |7 nnns 
773 1 8 |g volume:56  |g year:2018  |g number:9  |g day:19  |g month:09  |g pages:831-835 
856 4 0 |u http://dx.doi.org/10.1002/mrc.4744  |3 Volltext 