Feasibility of percutaneous closure of atrial septal defects in adults under transthoracic echocardiography guidance using the Figulla atrial septal defect occluder device

BACKGROUND: Closure of atrial septal defect (ASD) among adults under transthoracic echocardiography (TTE) guidance using devices other than the Amplatzer Septal Occluder has not been extensively tested

Bibliographische Detailangaben
Veröffentlicht in:Journal of the Saudi Heart Association. - 1999. - 30(2018), 1 vom: 26. Jan., Seite 21-27
1. Verfasser: Ali, Mahmoud (VerfasserIn)
Weitere Verfasser: Salah El-Din, Hesham, Bakhoum, Sameh, El-Sisi, Amal, Mahmood, Kareem, Farouk, Heba, Kandil, Hossam
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2018
Zugriff auf das übergeordnete Werk:Journal of the Saudi Heart Association
Schlagworte:Journal Article Atrial septal defect transcatheter closure device transthoracic echocardiography
LEADER 01000naa a22002652 4500
001 NLM279592922
003 DE-627
005 20231225023332.0
007 cr uuu---uuuuu
008 231225s2018 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jsha.2017.04.002  |2 doi 
028 5 2 |a pubmed24n0931.xml 
035 |a (DE-627)NLM279592922 
035 |a (NLM)29296061 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Ali, Mahmoud  |e verfasserin  |4 aut 
245 1 0 |a Feasibility of percutaneous closure of atrial septal defects in adults under transthoracic echocardiography guidance using the Figulla atrial septal defect occluder device 
264 1 |c 2018 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 11.03.2022 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a BACKGROUND: Closure of atrial septal defect (ASD) among adults under transthoracic echocardiography (TTE) guidance using devices other than the Amplatzer Septal Occluder has not been extensively tested 
520 |a AIM OF WORK: Assessment of the safety and efficiency of secundum ASD closure using the Occlutech Figulla ASD Occluder under TTE guidance in adult patients with hemodynamically significant secundum ASD 
520 |a METHODS: Twenty patients (mean age, 32.9 ± 9.7, 75% of them females) were enrolled in the study. All patients underwent TTE and transoesophageal echocardiography (TEE) to assess the characteristics of the ASD prior to percutaneous closure. Procedures were performed using the Figulla Occluder device under both fluoroscopic and TTE guidance. Follow-up clinical and TTE examinations were done at 1, 3, and 6 months following the procedure 
520 |a RESULTS: TTE estimated mean ASD size was 21.7 ± 7.3 mm with adequate rims except for the aortic rim (deficient in one third of cases). Mean device size was 28.1 ± 8.6 mm with mean procedure and fluoroscopic times of 46.2 ± 16.4 and 15.7 ± 5.4 minutes respectively. ASD was successfully closed in all patients. Two patients showed a small residual shunt immediately after the device placement that disappeared by the end of the 2nd followup TTE examination. Transient complications were detected in 2 patients. All patients were asymptomatic during the follow-up period 
520 |a CONCLUSION: Transcatheter closure of secundum ASD in adults under TTE guidance using the Occlutech Figulla ASD occluder device is safe and effective when performed in a tertiary center and by expert echocardiographers and interventional cardiologists 
650 4 |a Journal Article 
650 4 |a Atrial septal defect 
650 4 |a transcatheter closure device 
650 4 |a transthoracic echocardiography 
700 1 |a Salah El-Din, Hesham  |e verfasserin  |4 aut 
700 1 |a Bakhoum, Sameh  |e verfasserin  |4 aut 
700 1 |a El-Sisi, Amal  |e verfasserin  |4 aut 
700 1 |a Mahmood, Kareem  |e verfasserin  |4 aut 
700 1 |a Farouk, Heba  |e verfasserin  |4 aut 
700 1 |a Kandil, Hossam  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of the Saudi Heart Association  |d 1999  |g 30(2018), 1 vom: 26. Jan., Seite 21-27  |w (DE-627)NLM098225227  |x 1016-7315  |7 nnns 
773 1 8 |g volume:30  |g year:2018  |g number:1  |g day:26  |g month:01  |g pages:21-27 
856 4 0 |u http://dx.doi.org/10.1016/j.jsha.2017.04.002  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 30  |j 2018  |e 1  |b 26  |c 01  |h 21-27