Laser power meters as an X-ray power diagnostic for LCLS-II

For the LCLS-II X-ray instruments, laser power meters are being developed as compact X-ray power diagnostics to operate at soft and tender X-ray photon energies. These diagnostics can be installed at various locations along an X-ray free-electron laser (FEL) beamline in order to monitor the transmis...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 25(2018), Pt 1 vom: 01. Jan., Seite 72-76
1. Verfasser: Heimann, Philip (VerfasserIn)
Weitere Verfasser: Moeller, Stefan, Carbajo, Sergio, Song, Sanghoon, Dakovski, Georgi, Nordlund, Dennis, Fritz, David
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2018
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article X-ray free electron laser diagnostics power meter
LEADER 01000naa a22002652 4500
001 NLM27935424X
003 DE-627
005 20231225022753.0
007 cr uuu---uuuuu
008 231225s2018 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577517014096  |2 doi 
028 5 2 |a pubmed24n0931.xml 
035 |a (DE-627)NLM27935424X 
035 |a (NLM)29271754 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Heimann, Philip  |e verfasserin  |4 aut 
245 1 0 |a Laser power meters as an X-ray power diagnostic for LCLS-II 
264 1 |c 2018 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 20.11.2019 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a For the LCLS-II X-ray instruments, laser power meters are being developed as compact X-ray power diagnostics to operate at soft and tender X-ray photon energies. These diagnostics can be installed at various locations along an X-ray free-electron laser (FEL) beamline in order to monitor the transmission of X-ray optics along the beam path. In addition, the power meters will be used to determine the absolute X-ray power at the endstations. Here, thermopile power meters, which measure average power, and have been chosen primarily for their compatibility with the high repetition rates at LCLS-II, are evaluated. A number of characteristics in the soft X-ray range are presented including linearity, calibrations conducted with a photodiode and a gas monitor detector as well as ultra-high-vacuum compatibility tests using residual gas analysis. The application of these power meters for LCLS-II and other X-ray FEL sources is discussed 
650 4 |a Journal Article 
650 4 |a X-ray free electron laser 
650 4 |a diagnostics 
650 4 |a power meter 
700 1 |a Moeller, Stefan  |e verfasserin  |4 aut 
700 1 |a Carbajo, Sergio  |e verfasserin  |4 aut 
700 1 |a Song, Sanghoon  |e verfasserin  |4 aut 
700 1 |a Dakovski, Georgi  |e verfasserin  |4 aut 
700 1 |a Nordlund, Dennis  |e verfasserin  |4 aut 
700 1 |a Fritz, David  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 25(2018), Pt 1 vom: 01. Jan., Seite 72-76  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:25  |g year:2018  |g number:Pt 1  |g day:01  |g month:01  |g pages:72-76 
856 4 0 |u http://dx.doi.org/10.1107/S1600577517014096  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 25  |j 2018  |e Pt 1  |b 01  |c 01  |h 72-76