Thermogravimetric Analysis of Textile Dyeing Sludge (TDS) in N₂/CO₂/O₂ Atmospheres and its Combustion Model with Coal

  The combustion characteristics of textile dyeing sludge (TDS) in N2/O2, CO2/O2, and N2/CO2 atmospheres, and blends of TDS with coal were analyzed using TGA (thermogravimetric analysis). Results showed that the replacement of N2 by CO2 resulted in negative effects on the combustion and pyrolysis of...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Water environment research : a research publication of the Water Environment Federation. - 1998. - 90(2018), 1 vom: 01. Jan., Seite 30-41
1. Verfasser: Zhuo, Zhongxu (VerfasserIn)
Weitere Verfasser: Liu, Jingyong, Sun, Shuiyu, Kuo, Jiahong, Sun, Jian, Chang, Ken-Lin, Fu, Jiewen
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2018
Zugriff auf das übergeordnete Werk:Water environment research : a research publication of the Water Environment Federation
Schlagworte:Journal Article Coal Industrial Waste Sewage Water Pollutants, Chemical Carbon Dioxide 142M471B3J Nitrogen N762921K75 Oxygen S88TT14065