|
|
|
|
LEADER |
01000caa a22002652 4500 |
001 |
NLM276508823 |
003 |
DE-627 |
005 |
20240327233035.0 |
007 |
cr uuu---uuuuu |
008 |
231225s2017 xx |||||o 00| ||eng c |
024 |
7 |
|
|a 10.1109/TUFFC.2017.2758647
|2 doi
|
028 |
5 |
2 |
|a pubmed24n1350.xml
|
035 |
|
|
|a (DE-627)NLM276508823
|
035 |
|
|
|a (NLM)28981413
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Cunitz, Bryan W
|e verfasserin
|4 aut
|
245 |
1 |
0 |
|a Characterizing the Acoustic Output of an Ultrasonic Propulsion Device for Urinary Stones
|
264 |
|
1 |
|c 2017
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
500 |
|
|
|a Date Completed 29.03.2019
|
500 |
|
|
|a Date Revised 27.03.2024
|
500 |
|
|
|a published: Print-Electronic
|
500 |
|
|
|a Citation Status MEDLINE
|
520 |
|
|
|a A noninvasive ultrasound (US) system to facilitate the passage of small kidney stones has been developed. The device incorporates a software-based US platform programmed with brightness mode and Doppler for visualizing stones, plus long duration focused pulses for repositioning stones using the same transducer. This paper characterizes the acoustic outputs of the ultrasonic propulsion device. Though the application and outputs are unique, measurements were performed based on the regulatory standards for both diagnostic US and extracorporeal lithotripters. The extended length of the pulse, time varying pressure output over the pulse, the use of focused targeting, and the need to regulate the output at shallow depths, however, required modifications to the traditional acoustic measurement methods. Output parameters included spatial-peak intensities, mechanical index (MI), thermal index, pulse energy, focal geometry, and target accuracy. The imaging and Doppler operating modes of the system meet the Food and Drug Administration acoustic power and intensity limits for diagnostic US device. Push mode operates at a maximum MI of 2.2, which is above the limit of 1.9 for diagnostic US, but well below any lithotripsy device and an ISPTA of 548 mW/cm2, which is below the 720-mW/cm2 limit for diagnostic US
|
650 |
|
4 |
|a Journal Article
|
650 |
|
4 |
|a Research Support, N.I.H., Extramural
|
650 |
|
4 |
|a Research Support, U.S. Gov't, Non-P.H.S.
|
700 |
1 |
|
|a Dunmire, Barbrina
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Bailey, Michael R
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t IEEE transactions on ultrasonics, ferroelectrics, and frequency control
|d 1986
|g 64(2017), 12 vom: 05. Dez., Seite 1818-1827
|w (DE-627)NLM098181017
|x 1525-8955
|7 nnns
|
773 |
1 |
8 |
|g volume:64
|g year:2017
|g number:12
|g day:05
|g month:12
|g pages:1818-1827
|
856 |
4 |
0 |
|u http://dx.doi.org/10.1109/TUFFC.2017.2758647
|3 Volltext
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_22
|
912 |
|
|
|a GBV_ILN_24
|
912 |
|
|
|a GBV_ILN_350
|
951 |
|
|
|a AR
|
952 |
|
|
|d 64
|j 2017
|e 12
|b 05
|c 12
|h 1818-1827
|