Rayleigh SAW-Assisted SH-SAW Immunosensor on X-Cut 148-Y LiTaO3

In this paper, we describe a shear horizontal surface acoustic wave (SH-SAW) immunosensor that utilizes induce agitation by a Rayleigh SAW (R-SAW) on an X-cut 148-Y LiTaO3 substrate. On this substrate, SH-SAWs and R-SAWs with different frequencies can be effectively generated at an interdigital tran...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 64(2017), 9 vom: 01. Sept., Seite 1375-1381
1. Verfasser: Kogai, Takashi (VerfasserIn)
Weitere Verfasser: Yatsuda, Hiromi, Kondoh, Jun
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2017
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article
LEADER 01000caa a22002652 4500
001 NLM274573830
003 DE-627
005 20250222024145.0
007 cr uuu---uuuuu
008 231225s2017 xx |||||o 00| ||eng c
024 7 |a 10.1109/TUFFC.2017.2734282  |2 doi 
028 5 2 |a pubmed25n0915.xml 
035 |a (DE-627)NLM274573830 
035 |a (NLM)28783630 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Kogai, Takashi  |e verfasserin  |4 aut 
245 1 0 |a Rayleigh SAW-Assisted SH-SAW Immunosensor on X-Cut 148-Y LiTaO3 
264 1 |c 2017 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 15.11.2018 
500 |a Date Revised 15.11.2018 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a In this paper, we describe a shear horizontal surface acoustic wave (SH-SAW) immunosensor that utilizes induce agitation by a Rayleigh SAW (R-SAW) on an X-cut 148-Y LiTaO3 substrate. On this substrate, SH-SAWs and R-SAWs with different frequencies can be effectively generated at an interdigital transducer (IDT). First, to consider the power flow angles of SH-SAWs and R-SAWs on this substrate, the 360-MHz delay lines with six different tilt angles were designed and fabricated. From the experiments, an optimal power flow angle of 9° for the SH-SAW on this substrate is obtained. Second, in order to consider the immunoreactions of the SH-SAW immunosensors, a delay line with a tilt angle of 9° was designed and fabricated on this substrate. The delay line, which can generate two SAWs, namely, a 100-MHz SH-SAW and an 88.8-MHz R-SAW, has a propagation area covered with antigens of human serum albumin between transmitting and receiving IDTs. The immunoreactions caused by antigen-antibody binding events on the surface of the delay line were investigated on the basis of the velocity changes of the SH-SAWs for sensing with and without the assistance of an R-SAW. As a result, it was confirmed that the SH-SAW velocity changes due to antigen-antibody reactions can be markedly increased by the assistance of R-SAW agitation 
650 4 |a Journal Article 
700 1 |a Yatsuda, Hiromi  |e verfasserin  |4 aut 
700 1 |a Kondoh, Jun  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 64(2017), 9 vom: 01. Sept., Seite 1375-1381  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:64  |g year:2017  |g number:9  |g day:01  |g month:09  |g pages:1375-1381 
856 4 0 |u http://dx.doi.org/10.1109/TUFFC.2017.2734282  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 64  |j 2017  |e 9  |b 01  |c 09  |h 1375-1381