|
|
|
|
LEADER |
01000naa a22002652 4500 |
001 |
NLM274201070 |
003 |
DE-627 |
005 |
20231225002943.0 |
007 |
cr uuu---uuuuu |
008 |
231225s2017 xx |||||o 00| ||eng c |
024 |
7 |
|
|a 10.1002/adma.201702298
|2 doi
|
028 |
5 |
2 |
|a pubmed24n0914.xml
|
035 |
|
|
|a (DE-627)NLM274201070
|
035 |
|
|
|a (NLM)28745439
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Xu, Xiao-Yu
|e verfasserin
|4 aut
|
245 |
1 |
2 |
|a A Double-Stimuli-Responsive Fluorescent Center for Monitoring of Food Spoilage based on Dye Covalently Modified EuMOFs
|b From Sensory Hydrogels to Logic Devices
|
264 |
|
1 |
|c 2017
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
500 |
|
|
|a Date Completed 17.01.2019
|
500 |
|
|
|a Date Revised 30.09.2020
|
500 |
|
|
|a published: Print-Electronic
|
500 |
|
|
|a Citation Status MEDLINE
|
520 |
|
|
|a © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
|
520 |
|
|
|a Unsafe food is a huge threat to human health and the economy, and detecting food spoilage early is an ongoing and imperative need. Herein, a simple and effective strategy combining a fluorescence sensor and one-to-two logic operation is designed for monitoring biogenic amines, indicators of food spoilage. Sensors (methyl redlanthanide metal-organic frameworks (MR@EuMOFs)) are created by covalently modifying MR into NH2 -rich EuMOFs, which have a high quantum yield (48%). A double-stimuli-responsive fluorescence center is produced via energy transfer from the ligands to Eu3+ and MR. Portable sensory hydrogels are obtained by dispersing and solidifying MR@EuMOFs in water-phase sodium salt of carboxy methyl cellulose (CMC-Na). The hydrogels exhibit a color transition upon "smelling" histamine (HI) vapor. This transition and shift in the MR-based emission peak are closely related to the HI concentration. Using the HI concentration as the input signal and the two fluorescence emissions as output signals, an advanced analytical device based on a one-to-two logic gate is constructed. The four output combinations, NOT (0, 1), YES (1, 0), PASS 1 (1, 1), and PASS 0 (0, 0), allow the direct analysis of HI levels, which can be used for real-time food-freshness evaluation. The novel strategy suggested here may be a new application for a molecular logic system in the sensing field
|
650 |
|
4 |
|a Journal Article
|
650 |
|
4 |
|a fluorescence sensory hydrogels
|
650 |
|
4 |
|a food-spoilage monitoring
|
650 |
|
4 |
|a logic operation
|
650 |
|
4 |
|a methyl red covalently modified EuMOFs
|
650 |
|
7 |
|a Coloring Agents
|2 NLM
|
650 |
|
7 |
|a Hydrogels
|2 NLM
|
650 |
|
7 |
|a Water
|2 NLM
|
650 |
|
7 |
|a 059QF0KO0R
|2 NLM
|
700 |
1 |
|
|a Lian, Xiao
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Hao, Ji-Na
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Zhang, Chi
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Yan, Bing
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Advanced materials (Deerfield Beach, Fla.)
|d 1998
|g 29(2017), 37 vom: 19. Okt.
|w (DE-627)NLM098206397
|x 1521-4095
|7 nnns
|
773 |
1 |
8 |
|g volume:29
|g year:2017
|g number:37
|g day:19
|g month:10
|
856 |
4 |
0 |
|u http://dx.doi.org/10.1002/adma.201702298
|3 Volltext
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_350
|
951 |
|
|
|a AR
|
952 |
|
|
|d 29
|j 2017
|e 37
|b 19
|c 10
|