Further steps in the standardization of BOD5/COD ratio as a biological stability index for MSW

Copyright © 2017 Elsevier Ltd. All rights reserved.

Bibliographische Detailangaben
Veröffentlicht in:Waste management (New York, N.Y.). - 1999. - 68(2017) vom: 15. Okt., Seite 16-23
1. Verfasser: Cossu, R (VerfasserIn)
Weitere Verfasser: Fantinato, G, Pivato, A, Sandon, A
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2017
Zugriff auf das übergeordnete Werk:Waste management (New York, N.Y.)
Schlagworte:Journal Article BOD5/COD ratio Biological stability index Respirometric index Water Pollutants, Chemical Water 059QF0KO0R
LEADER 01000naa a22002652 4500
001 NLM273329650
003 DE-627
005 20231225000955.0
007 cr uuu---uuuuu
008 231225s2017 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.wasman.2017.06.035  |2 doi 
028 5 2 |a pubmed24n0911.xml 
035 |a (DE-627)NLM273329650 
035 |a (NLM)28655463 
035 |a (PII)S0956-053X(17)30476-2 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Cossu, R  |e verfasserin  |4 aut 
245 1 0 |a Further steps in the standardization of BOD5/COD ratio as a biological stability index for MSW 
264 1 |c 2017 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 13.12.2017 
500 |a Date Revised 02.12.2018 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a Copyright © 2017 Elsevier Ltd. All rights reserved. 
520 |a In recent decades the definition of standard test methodologies suitable for use in assessing the biological stability of solid waste has become increasingly imperative. To meet this requirement, the BOD5/COD ratio, measured on waste eluate, has been proposed by Cossu et al. (2012) as a more appropriate parameter than the traditional respirometric indices and biogas production measured directly on solid samples. However, to ensure reproducibility, the parameter should undergo standardization of operational conditions. Previous studies have demonstrated that: the testing mode (static or dynamic) does not influence test representativeness; the long testing time (>6h) does not influence BOD5/COD ratio; COD measured on unfiltered or filtered samples is consistent and significant in both cases. The main aim of this study was to further promote the standardization of this parameter. A series of static leaching tests on representative samples of five types of waste was carried out under different operative conditions: contact time, liquid to solid ratio and pretreatment. The results obtained demonstrate: the apparent adequacy of a short contact time (2h), which is highly preferable and would speed up the procedure; a low liquid to solid ratio (5 l/kgTS) which is recommended as a water saving strategy; the applicability of centrifugation of the eluate prior to analysis which is faster that filtration method 
650 4 |a Journal Article 
650 4 |a BOD5/COD ratio 
650 4 |a Biological stability index 
650 4 |a Respirometric index 
650 7 |a Water Pollutants, Chemical  |2 NLM 
650 7 |a Water  |2 NLM 
650 7 |a 059QF0KO0R  |2 NLM 
700 1 |a Fantinato, G  |e verfasserin  |4 aut 
700 1 |a Pivato, A  |e verfasserin  |4 aut 
700 1 |a Sandon, A  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Waste management (New York, N.Y.)  |d 1999  |g 68(2017) vom: 15. Okt., Seite 16-23  |w (DE-627)NLM098197061  |x 1879-2456  |7 nnns 
773 1 8 |g volume:68  |g year:2017  |g day:15  |g month:10  |g pages:16-23 
856 4 0 |u http://dx.doi.org/10.1016/j.wasman.2017.06.035  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 68  |j 2017  |b 15  |c 10  |h 16-23