Model-based methodology for the design of optimal control strategies in MBR plants

This paper proposes a model-based methodology that allows synthesising the most appropriate strategies for optimising the operation of wastewater treatment plants (WWTPs). The methodology is applied with the aim of maximising the nitrogen removal in membrane bioreactors (MBRs). The proposed procedur...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Water science and technology : a journal of the International Association on Water Pollution Research. - 1986. - 75(2017), 11-12 vom: 20. Juni, Seite 2546-2553
1. Verfasser: Odriozola, Juan (VerfasserIn)
Weitere Verfasser: Beltrán, Sergio, Dalmau, Montse, Sancho, Luis, Comas, Joaquim, Rodríguez-Roda, Ignasi, Ayesa, Eduardo
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2017
Zugriff auf das übergeordnete Werk:Water science and technology : a journal of the International Association on Water Pollution Research
Schlagworte:Journal Article Membranes, Artificial Waste Water Nitrogen N762921K75
LEADER 01000naa a22002652 4500
001 NLM272958875
003 DE-627
005 20231225000009.0
007 cr uuu---uuuuu
008 231225s2017 xx |||||o 00| ||eng c
024 7 |a 10.2166/wst.2017.135  |2 doi 
028 5 2 |a pubmed24n0909.xml 
035 |a (DE-627)NLM272958875 
035 |a (NLM)28617273 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Odriozola, Juan  |e verfasserin  |4 aut 
245 1 0 |a Model-based methodology for the design of optimal control strategies in MBR plants 
264 1 |c 2017 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 17.08.2017 
500 |a Date Revised 07.12.2022 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a This paper proposes a model-based methodology that allows synthesising the most appropriate strategies for optimising the operation of wastewater treatment plants (WWTPs). The methodology is applied with the aim of maximising the nitrogen removal in membrane bioreactors (MBRs). The proposed procedure is based on a systematic approach composed of four steps. First, a sensitivity analysis of the input variables is carried out in order to obtain a first assessment of the potential for operational improvements. Then, the optimum input variable values are calculated by a model-based optimisation algorithm that minimises a cost function associated with the effluent total nitrogen at different temperatures. Then, the optimum operational strategies are identified. Finally, these operational strategies form the conceptual knowledge base for designing automatic control laws. The obtained optimal control strategies have shown a significant improvement in performance in comparison with fixed operation for the studied case, reducing the total nitrogen by 40% 
650 4 |a Journal Article 
650 7 |a Membranes, Artificial  |2 NLM 
650 7 |a Waste Water  |2 NLM 
650 7 |a Nitrogen  |2 NLM 
650 7 |a N762921K75  |2 NLM 
700 1 |a Beltrán, Sergio  |e verfasserin  |4 aut 
700 1 |a Dalmau, Montse  |e verfasserin  |4 aut 
700 1 |a Sancho, Luis  |e verfasserin  |4 aut 
700 1 |a Comas, Joaquim  |e verfasserin  |4 aut 
700 1 |a Rodríguez-Roda, Ignasi  |e verfasserin  |4 aut 
700 1 |a Ayesa, Eduardo  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Water science and technology : a journal of the International Association on Water Pollution Research  |d 1986  |g 75(2017), 11-12 vom: 20. Juni, Seite 2546-2553  |w (DE-627)NLM098149431  |x 0273-1223  |7 nnns 
773 1 8 |g volume:75  |g year:2017  |g number:11-12  |g day:20  |g month:06  |g pages:2546-2553 
856 4 0 |u http://dx.doi.org/10.2166/wst.2017.135  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 75  |j 2017  |e 11-12  |b 20  |c 06  |h 2546-2553