Xylem resistance to embolism : presenting a simple diagnostic test for the open vessel artefact

© 2017 The Authors. New Phytologist © 2017 New Phytologist Trust.

Détails bibliographiques
Publié dans:The New phytologist. - 1979. - 215(2017), 1 vom: 27. Juli, Seite 489-499
Auteur principal: Torres-Ruiz, José M (Auteur)
Autres auteurs: Cochard, Hervé, Choat, Brendan, Jansen, Steven, López, Rosana, Tomášková, Ivana, Padilla-Díaz, Carmen M, Badel, Eric, Burlett, Regis, King, Andrew, Lenoir, Nicolas, Martin-StPaul, Nicolas K, Delzon, Sylvain
Format: Article en ligne
Langue:English
Publié: 2017
Accès à la collection:The New phytologist
Sujets:Journal Article artefact centrifuge technique embolism micro-CT olive xylem Water 059QF0KO0R
LEADER 01000caa a22002652c 4500
001 NLM271532203
003 DE-627
005 20250221142830.0
007 cr uuu---uuuuu
008 231224s2017 xx |||||o 00| ||eng c
024 7 |a 10.1111/nph.14589  |2 doi 
028 5 2 |a pubmed25n0905.xml 
035 |a (DE-627)NLM271532203 
035 |a (NLM)28467616 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Torres-Ruiz, José M  |e verfasserin  |4 aut 
245 1 0 |a Xylem resistance to embolism  |b presenting a simple diagnostic test for the open vessel artefact 
264 1 |c 2017 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 01.05.2018 
500 |a Date Revised 30.09.2020 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a © 2017 The Authors. New Phytologist © 2017 New Phytologist Trust. 
520 |a Xylem vulnerability to embolism represents an essential trait for the evaluation of the impact of hydraulics in plant function and ecology. The standard centrifuge technique is widely used for the construction of vulnerability curves, although its accuracy when applied to species with long vessels remains under debate. We developed a simple diagnostic test to determine whether the open-vessel artefact influences centrifuge estimates of embolism resistance. Xylem samples from three species with differing vessel lengths were exposed to less negative xylem pressures via centrifugation than the minimum pressure the sample had previously experienced. Additional calibration was obtained from non-invasive measurement of embolism on intact olive plants by X-ray microtomography. Results showed artefactual decreases in hydraulic conductance (k) for samples with open vessels when exposed to a less negative xylem pressure than the minimum pressure they had previously experienced. X-Ray microtomography indicated that most of the embolism formation in olive occurs at xylem pressures below -4.0 MPa, reaching 50% loss of hydraulic conductivity at -5.3 MPa. The artefactual reductions in k induced by centrifugation underestimate embolism resistance data of species with long vessels. A simple test is suggested to avoid this open vessel artefact and to ensure the reliability of this technique in future studies 
650 4 |a Journal Article 
650 4 |a artefact 
650 4 |a centrifuge technique 
650 4 |a embolism 
650 4 |a micro-CT 
650 4 |a olive 
650 4 |a xylem 
650 7 |a Water  |2 NLM 
650 7 |a 059QF0KO0R  |2 NLM 
700 1 |a Cochard, Hervé  |e verfasserin  |4 aut 
700 1 |a Choat, Brendan  |e verfasserin  |4 aut 
700 1 |a Jansen, Steven  |e verfasserin  |4 aut 
700 1 |a López, Rosana  |e verfasserin  |4 aut 
700 1 |a Tomášková, Ivana  |e verfasserin  |4 aut 
700 1 |a Padilla-Díaz, Carmen M  |e verfasserin  |4 aut 
700 1 |a Badel, Eric  |e verfasserin  |4 aut 
700 1 |a Burlett, Regis  |e verfasserin  |4 aut 
700 1 |a King, Andrew  |e verfasserin  |4 aut 
700 1 |a Lenoir, Nicolas  |e verfasserin  |4 aut 
700 1 |a Martin-StPaul, Nicolas K  |e verfasserin  |4 aut 
700 1 |a Delzon, Sylvain  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t The New phytologist  |d 1979  |g 215(2017), 1 vom: 27. Juli, Seite 489-499  |w (DE-627)NLM09818248X  |x 1469-8137  |7 nnas 
773 1 8 |g volume:215  |g year:2017  |g number:1  |g day:27  |g month:07  |g pages:489-499 
856 4 0 |u http://dx.doi.org/10.1111/nph.14589  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 215  |j 2017  |e 1  |b 27  |c 07  |h 489-499