Facilitating the performance of qNMR analysis using automated quantification and results verification

Copyright © 2017 John Wiley & Sons, Ltd.

Bibliographische Detailangaben
Veröffentlicht in:Magnetic resonance in chemistry : MRC. - 1985. - 55(2017), 9 vom: 20. Sept., Seite 813-820
1. Verfasser: Monakhova, Yulia B (VerfasserIn)
Weitere Verfasser: Diehl, Bernd W K
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2017
Zugriff auf das übergeordnete Werk:Magnetic resonance in chemistry : MRC
Schlagworte:Journal Article automation internal standards pharmaceutical products purity qNMR
LEADER 01000naa a22002652 4500
001 NLM269861092
003 DE-627
005 20231224225355.0
007 cr uuu---uuuuu
008 231224s2017 xx |||||o 00| ||eng c
024 7 |a 10.1002/mrc.4591  |2 doi 
028 5 2 |a pubmed24n0899.xml 
035 |a (DE-627)NLM269861092 
035 |a (NLM)28295588 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Monakhova, Yulia B  |e verfasserin  |4 aut 
245 1 0 |a Facilitating the performance of qNMR analysis using automated quantification and results verification 
264 1 |c 2017 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 05.03.2018 
500 |a Date Revised 05.03.2018 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Copyright © 2017 John Wiley & Sons, Ltd. 
520 |a Quantitative nuclear magnetic resonance (qNMR) is considered as a powerful tool for measuring the absolute amount of small molecules in complex mixtures. However, verification of the accuracy of such quantification is not a trivial task. In particular, preprocessing and integration steps are challenging and potentially erroneous. A script was developed in Matlab environment to automate qNMR analysis. Verification of the results is based on two evolving integration profiles. The analysis of binary mixtures of internal standards as well as pharmaceutical products has shown that all common artifacts (phase and baseline distortion, impurities) can be easily recognized in routine qNMR experiments. In the absence of distortion, deviation between automatically (mean value of several integrals) and manually calculated values was generally below 0.1%. The routine is independent of multiplet pattern, solvent, spectrometer, nuclei type and pulse sequence used. In general, the usage of the developed script can facilitate and verify results of routine qNMR analysis in an automatic manner. Copyright © 2017 John Wiley & Sons, Ltd 
650 4 |a Journal Article 
650 4 |a automation 
650 4 |a internal standards 
650 4 |a pharmaceutical products 
650 4 |a purity 
650 4 |a qNMR 
700 1 |a Diehl, Bernd W K  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Magnetic resonance in chemistry : MRC  |d 1985  |g 55(2017), 9 vom: 20. Sept., Seite 813-820  |w (DE-627)NLM098179667  |x 1097-458X  |7 nnns 
773 1 8 |g volume:55  |g year:2017  |g number:9  |g day:20  |g month:09  |g pages:813-820 
856 4 0 |u http://dx.doi.org/10.1002/mrc.4591  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 55  |j 2017  |e 9  |b 20  |c 09  |h 813-820