A Backprojection-Based Parameter Estimation Technique for Skew-Slit Collimation

To estimate geometric parameters in a skew-slit single photon emission computed tomography (SPECT) scan, a simple method is presented that uses a single point source and a backprojection process. The method employs one point source placed sufficiently far from the axis of rotation but in the field o...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on nuclear science. - 1988. - 56(2009), 3 vom: 20., Seite 687-693
1. Verfasser: Piatt, Jacob A (VerfasserIn)
Weitere Verfasser: Zeng, Gengsheng L
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2009
Zugriff auf das übergeordnete Werk:IEEE transactions on nuclear science
Schlagworte:Journal Article Acquisition geometry SPECT computed tomography parameter estimation pinhole skew-slit
LEADER 01000caa a22002652 4500
001 NLM269112030
003 DE-627
005 20250221064738.0
007 cr uuu---uuuuu
008 231224s2009 xx |||||o 00| ||eng c
024 7 |a 10.1109/TNS.2009.2019110  |2 doi 
028 5 2 |a pubmed25n0896.xml 
035 |a (DE-627)NLM269112030 
035 |a (NLM)28216696 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Piatt, Jacob A  |e verfasserin  |4 aut 
245 1 2 |a A Backprojection-Based Parameter Estimation Technique for Skew-Slit Collimation 
264 1 |c 2009 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 20.11.2019 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a To estimate geometric parameters in a skew-slit single photon emission computed tomography (SPECT) scan, a simple method is presented that uses a single point source and a backprojection process. The method employs one point source placed sufficiently far from the axis of rotation but in the field of view. A skew-slit geometry is considered where the estimated parameters include the focal lengths of both opaque planes and the location of multiple transaxial slits and a single axial slit. Computer simulations show that view-angle independent parameters can be uniquely estimated. Three experimental scans were performed, and the view-angle independent parameters were accurately estimated. Tilt, sagging, and mechanical shifts result in parameters that change depending on the view angle in the experimental scans. These view-angle dependent parameters were estimated using the single point-source technique, but reconstructed phantom images showed some error in the estimation of the view-angle dependent parameters 
650 4 |a Journal Article 
650 4 |a Acquisition geometry 
650 4 |a SPECT 
650 4 |a computed tomography 
650 4 |a parameter estimation 
650 4 |a pinhole 
650 4 |a skew-slit 
700 1 |a Zeng, Gengsheng L  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on nuclear science  |d 1988  |g 56(2009), 3 vom: 20., Seite 687-693  |w (DE-627)NLM098149350  |x 0018-9499  |7 nnns 
773 1 8 |g volume:56  |g year:2009  |g number:3  |g day:20  |g pages:687-693 
856 4 0 |u http://dx.doi.org/10.1109/TNS.2009.2019110  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 56  |j 2009  |e 3  |b 20  |h 687-693