|
|
|
|
LEADER |
01000naa a22002652 4500 |
001 |
NLM268250138 |
003 |
DE-627 |
005 |
20231224222315.0 |
007 |
cr uuu---uuuuu |
008 |
231224s2016 xx |||||o 00| ||eng c |
024 |
7 |
|
|a 10.1109/TUFFC.2016.2570898
|2 doi
|
028 |
5 |
2 |
|a pubmed24n0894.xml
|
035 |
|
|
|a (DE-627)NLM268250138
|
035 |
|
|
|a (NLM)28113421
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Abgrall, Michel
|e verfasserin
|4 aut
|
245 |
1 |
0 |
|a High Stability Comparison of Atomic Fountains using two Different Cryogenic Oscillators
|
264 |
|
1 |
|c 2016
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
500 |
|
|
|a Date Revised 20.11.2019
|
500 |
|
|
|a published: Print-Electronic
|
500 |
|
|
|a Citation Status PubMed-not-MEDLINE
|
520 |
|
|
|a We present a detailed characterization of two atomic clock interrogation systems based on two different cryogenic sapphire oscillators operated simultaneously. We use them as references for two accurate fountain clock frequency standards participating in international atomic time and operating both at the quantum projection noise frequency limit. The two fountain comparison down to a few 10 16 over 28 days demonstrates the potential of a cryocooled oscillator to replace a He refilled cryogenic oscillator
|
650 |
|
4 |
|a Journal Article
|
700 |
1 |
|
|a Guena, Jocelyne
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Lours, Michel
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Santarelli, Giorgio
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Tobar, Michael
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Bize, Sebastien
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Grop, Serge
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Dubois, Benoit
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Fluhr, Christophe
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Giordano, Vincent
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t IEEE transactions on ultrasonics, ferroelectrics, and frequency control
|d 1986
|g 63(2016), 8 vom: 15. Aug., Seite 1198-1203
|w (DE-627)NLM098181017
|x 1525-8955
|7 nnns
|
773 |
1 |
8 |
|g volume:63
|g year:2016
|g number:8
|g day:15
|g month:08
|g pages:1198-1203
|
856 |
4 |
0 |
|u http://dx.doi.org/10.1109/TUFFC.2016.2570898
|3 Volltext
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_22
|
912 |
|
|
|a GBV_ILN_24
|
912 |
|
|
|a GBV_ILN_350
|
951 |
|
|
|a AR
|
952 |
|
|
|d 63
|j 2016
|e 8
|b 15
|c 08
|h 1198-1203
|