Effect of mean cell residence time on transmembrane flux, mixed-liquor characteristics and overall performance of a submerged anaerobic membrane bioreactor
Kinetic control of Mean Cell Residence Time (MCRT) was shown to have a significant impact on membrane flux under steady-state conditions. Two laboratory-scale flat-plate submerged anaerobic membrane bioreactors were operated for 245 days on a low-to-intermediate strength substrate with high suspende...
Publié dans: | Environmental technology. - 1993. - 38(2017), 10 vom: 02. Mai, Seite 1263-1274 |
---|---|
Auteur principal: | |
Autres auteurs: | , |
Format: | Article en ligne |
Langue: | English |
Publié: |
2017
|
Accès à la collection: | Environmental technology |
Sujets: | Journal Article Anaerobic membrane bioreactors kinetic control mean cell residence time membrane fouling wastewater treatment Membranes, Artificial Sewage Methane OP0UW79H66 |