30-Lens interferometer for high-energy X-rays

A novel high-energy multi-lens interferometer consisting of 30 arrays of planar compound refractive lenses is reported. Under coherent illumination each lens array creates a diffraction-limited secondary source. Overlapping such coherent beams produces an interference pattern demonstrating strong lo...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 23(2016), Pt 5 vom: 01. Sept., Seite 1104-9
1. Verfasser: Lyubomirskiy, Mikhail (VerfasserIn)
Weitere Verfasser: Snigireva, Irina, Kohn, Victor, Kuznetsov, Sergey, Yunkin, Vyacheslav, Vaughan, Gavin, Snigirev, Anatoly
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2016
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Research Support, Non-U.S. Gov't MEMS Si lenses Talbot effect coherence interferometry
LEADER 01000naa a22002652 4500
001 NLM26390220X
003 DE-627
005 20231224204918.0
007 cr uuu---uuuuu
008 231224s2016 xx |||||o 00| ||eng c
024 7 |a 10.1107/S160057751601153X  |2 doi 
028 5 2 |a pubmed24n0879.xml 
035 |a (DE-627)NLM26390220X 
035 |a (NLM)27577763 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Lyubomirskiy, Mikhail  |e verfasserin  |4 aut 
245 1 0 |a 30-Lens interferometer for high-energy X-rays 
264 1 |c 2016 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 21.08.2018 
500 |a Date Revised 21.08.2018 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a A novel high-energy multi-lens interferometer consisting of 30 arrays of planar compound refractive lenses is reported. Under coherent illumination each lens array creates a diffraction-limited secondary source. Overlapping such coherent beams produces an interference pattern demonstrating strong longitudinal functional dependence. The proposed multi-lens interferometer was tested experimentally at the 100 m-long ID11 ESRF beamline in the X-ray energy range from 30 to 65 keV. The interference pattern generated by the interferometer was recorded at fundamental and fractional Talbot distances. An effective source size (FWHM) of the order of 15 µm was determined from the first Talbot image, proving the concept that the multi-lens interferometer can be used as a high-resolution tool for beam diagnostics 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 4 |a MEMS 
650 4 |a Si lenses 
650 4 |a Talbot effect 
650 4 |a coherence 
650 4 |a interferometry 
700 1 |a Snigireva, Irina  |e verfasserin  |4 aut 
700 1 |a Kohn, Victor  |e verfasserin  |4 aut 
700 1 |a Kuznetsov, Sergey  |e verfasserin  |4 aut 
700 1 |a Yunkin, Vyacheslav  |e verfasserin  |4 aut 
700 1 |a Vaughan, Gavin  |e verfasserin  |4 aut 
700 1 |a Snigirev, Anatoly  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 23(2016), Pt 5 vom: 01. Sept., Seite 1104-9  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:23  |g year:2016  |g number:Pt 5  |g day:01  |g month:09  |g pages:1104-9 
856 4 0 |u http://dx.doi.org/10.1107/S160057751601153X  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 23  |j 2016  |e Pt 5  |b 01  |c 09  |h 1104-9