Design and Fabrication of a Conceptual Arterial Ultrasound Phantom Capable of Exhibiting Longitudinal Wall Movement

The longitudinal movement of the arterial wall of large human arteries has shown promise to be an independent indicator of vascular health. Despite growing interest in this movement, its nature, causes, and implications are not fully understood, and existing phantoms have failed to show a pure longi...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 64(2017), 1 vom: 12. Jan., Seite 11-18
1. Verfasser: Sjostrand, Sandra (VerfasserIn)
Weitere Verfasser: Widerstrom, Alice, Ahlgren, Asa Ryden, Cinthio, Magnus
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2017
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article Research Support, Non-U.S. Gov't
LEADER 01000naa a22002652 4500
001 NLM263480429
003 DE-627
005 20231224204012.0
007 cr uuu---uuuuu
008 231224s2017 xx |||||o 00| ||eng c
024 7 |a 10.1109/TUFFC.2016.2597246  |2 doi 
028 5 2 |a pubmed24n0878.xml 
035 |a (DE-627)NLM263480429 
035 |a (NLM)27529873 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Sjostrand, Sandra  |e verfasserin  |4 aut 
245 1 0 |a Design and Fabrication of a Conceptual Arterial Ultrasound Phantom Capable of Exhibiting Longitudinal Wall Movement 
264 1 |c 2017 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 26.11.2018 
500 |a Date Revised 26.11.2018 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a The longitudinal movement of the arterial wall of large human arteries has shown promise to be an independent indicator of vascular health. Despite growing interest in this movement, its nature, causes, and implications are not fully understood, and existing phantoms have failed to show a pure longitudinal movement that is not secondary to the distension. An often overlooked aspect of the arterial wall is the interaction between the different layers. The longitudinal movement of the innermost layers, the intima and media, can be several hundred micrometers in the direction of flow during early systole. This is markedly larger than that of the adventitia, indicating that sliding occurs between the two layers. This feature was incorporated into a phantom by casting it in two parts. The molds were developed in-house using mainly a 3-D printer, a versatile and easy production method. Additionally, the phantom contains a tapered region. Using the phantom, we were able to demonstrate a pure longitudinal movement; when it was subjected to a pulsatile pressure, the wall displaced 220 [Formula: see text] (SD 40) radially and 560 [Formula: see text] (SD 74) longitudinally distal to the tapering. The motion followed the pressure variations. This paper serves as a guide for phantom production, explaining each step of the process 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Widerstrom, Alice  |e verfasserin  |4 aut 
700 1 |a Ahlgren, Asa Ryden  |e verfasserin  |4 aut 
700 1 |a Cinthio, Magnus  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 64(2017), 1 vom: 12. Jan., Seite 11-18  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:64  |g year:2017  |g number:1  |g day:12  |g month:01  |g pages:11-18 
856 4 0 |u http://dx.doi.org/10.1109/TUFFC.2016.2597246  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 64  |j 2017  |e 1  |b 12  |c 01  |h 11-18