Evaluation of an automatic image-based screening technique for neonatal hyperbilirubinemia

OBJECTIVE: To verify the accuracy of a smart phone software application, which is an automated image-based bilirubin (AIB) testing technique for testing peripheral blood total bilirubin (TB) in term and late preterm neonates

Bibliographische Detailangaben
Veröffentlicht in:Zhonghua er ke za zhi = Chinese journal of pediatrics. - 1960. - 54(2016), 8 vom: 11. Aug., Seite 597-600
1. Verfasser: Rong, Z H (VerfasserIn)
Weitere Verfasser: Luo, F, Ma, L Y, Chen, L, Wu, L, Liu, W, Du, L Z, Luo, X P
Format: Online-Aufsatz
Sprache:Chinese
Veröffentlicht: 2016
Zugriff auf das übergeordnete Werk:Zhonghua er ke za zhi = Chinese journal of pediatrics
Schlagworte:Journal Article Bilirubin RFM9X3LJ49
LEADER 01000naa a22002652 4500
001 NLM263307697
003 DE-627
005 20231224203623.0
007 cr uuu---uuuuu
008 231224s2016 xx |||||o 00| ||chi c
024 7 |a 10.3760/cma.j.issn.0578-1310.2016.08.008  |2 doi 
028 5 2 |a pubmed24n0877.xml 
035 |a (DE-627)NLM263307697 
035 |a (NLM)27510872 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a chi 
100 1 |a Rong, Z H  |e verfasserin  |4 aut 
245 1 0 |a Evaluation of an automatic image-based screening technique for neonatal hyperbilirubinemia 
264 1 |c 2016 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 26.07.2017 
500 |a Date Revised 02.12.2018 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a OBJECTIVE: To verify the accuracy of a smart phone software application, which is an automated image-based bilirubin (AIB) testing technique for testing peripheral blood total bilirubin (TB) in term and late preterm neonates 
520 |a METHOD: During July 2015 to January 2016, jaundiced neonates were enrolled from department of neonatology in Tongji Hospital, Children's Hospital of Zhejiang University School of Medicine and Shenzhen Bao'an Maternal and Child Health Hospital. The enrolling criteria included gestational age (GA)≥34 weeks and peripheral blood total bilirubin test is required. Near-simultaneous TB, transcutaneous bilirubin (TcB), and AIB were determined. AIB consists of a cloud based off-line learning module and an on-line prediction module. Skin image, by smart phone is uploaded to a specific cloud server that includes learning based software to provide an individualized and immediate predicted bilirubin index. The t-test was used to determine if AIB and peripheral blood TB are significantly different. Agreement of AIB and TcB were compared with peripheral blood TB by Bland-Altman analysis. Linear regression was adopted to model the relationship of AIB and peripheral blood TB. The ROC curve of AIB was also plotted 
520 |a RESULT: Two hundred and fifteen neonates were enrolled, gestational age 37 weeks+ 5 d, postnatal age (11±4) d, weight (2.9±0.7) kg, 116 male and 99 female. One hundred and forty-eight term neonates (GA≥37 weeks) and 67 preterm neonates (GA 34-<37 weeks) were enrolled in this study. There was no significant difference between AIB (197±51)μmol/L and peripheral blood TB(191±65)μmol/L (t=1.611, P=0.109). There was strong relevance between peripheral blood TB and AIB as shown by Bland-Altman analysis (96% (207/215) samples lay within the 95% limits of agreement). The regression analysis showed that the r(2) was 0.593 in the whole population, while the r(2) was 0.628 in the term neonates. The ROC of AIB yielded a 0.743 AUC, and with 82% sensitivity and 60% specificity based on Youden index criterion 
520 |a CONCLUSION: Based on AIB's agreement with peripheral blood TB, the sensitivity and specificity, AIB can be used as a new technique to provide results for objective follow-up for progression and regression of jaundice 
650 4 |a Journal Article 
650 7 |a Bilirubin  |2 NLM 
650 7 |a RFM9X3LJ49  |2 NLM 
700 1 |a Luo, F  |e verfasserin  |4 aut 
700 1 |a Ma, L Y  |e verfasserin  |4 aut 
700 1 |a Chen, L  |e verfasserin  |4 aut 
700 1 |a Wu, L  |e verfasserin  |4 aut 
700 1 |a Liu, W  |e verfasserin  |4 aut 
700 1 |a Du, L Z  |e verfasserin  |4 aut 
700 1 |a Luo, X P  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Zhonghua er ke za zhi = Chinese journal of pediatrics  |d 1960  |g 54(2016), 8 vom: 11. Aug., Seite 597-600  |w (DE-627)NLM136249191  |x 0578-1310  |7 nnns 
773 1 8 |g volume:54  |g year:2016  |g number:8  |g day:11  |g month:08  |g pages:597-600 
856 4 0 |u http://dx.doi.org/10.3760/cma.j.issn.0578-1310.2016.08.008  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_11 
912 |a GBV_ILN_20 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_31 
912 |a GBV_ILN_39 
912 |a GBV_ILN_40 
912 |a GBV_ILN_50 
912 |a GBV_ILN_61 
912 |a GBV_ILN_65 
912 |a GBV_ILN_69 
912 |a GBV_ILN_70 
912 |a GBV_ILN_72 
912 |a GBV_ILN_120 
912 |a GBV_ILN_130 
912 |a GBV_ILN_227 
912 |a GBV_ILN_244 
912 |a GBV_ILN_285 
912 |a GBV_ILN_294 
912 |a GBV_ILN_350 
912 |a GBV_ILN_665 
912 |a GBV_ILN_813 
951 |a AR 
952 |d 54  |j 2016  |e 8  |b 11  |c 08  |h 597-600