|
|
|
|
LEADER |
01000naa a22002652 4500 |
001 |
NLM263268713 |
003 |
DE-627 |
005 |
20231224203531.0 |
007 |
cr uuu---uuuuu |
008 |
231224s2016 xx |||||o 00| ||eng c |
024 |
7 |
|
|a 10.1021/acs.langmuir.6b02564
|2 doi
|
028 |
5 |
2 |
|a pubmed24n0877.xml
|
035 |
|
|
|a (DE-627)NLM263268713
|
035 |
|
|
|a (NLM)27506399
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Chen, Pin
|e verfasserin
|4 aut
|
245 |
1 |
0 |
|a Evaporation of Binary Sessile Drops
|b Infrared and Acoustic Methods To Track Alcohol Concentration at the Interface and on the Surface
|
264 |
|
1 |
|c 2016
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
500 |
|
|
|a Date Completed 06.06.2018
|
500 |
|
|
|a Date Revised 06.06.2018
|
500 |
|
|
|a published: Print-Electronic
|
500 |
|
|
|a Citation Status PubMed-not-MEDLINE
|
520 |
|
|
|a Evaporation of droplets of three pure liquids (water, 1-butanol, and ethanol) and four binary solutions (5 wt % 1-butanol-water-based solution and 5, 25, and 50 wt % ethanol-water-based solutions) deposited on hydrophobic silicon was investigated. A drop shape analyzer was used to measure the contact angle, diameter, and volume of the droplets. An infrared camera was used for infrared thermal mapping of the droplet's surface. An acoustic high-frequency echography technique was, for the first time, applied to track the alcohol concentration in a binary-solution droplet. Evaporation of pure alcohol droplets was executed at different values of relative humidity (RH), among which the behavior of pure ethanol evaporation was notably influenced by the ambient humidity as a result of high hygrometry. Evaporation of droplets of water and binary solutions was performed at a temperature of 22 °C and a mean humidity of approximately 50%. The exhaustion times of alcohol in the droplets estimated by the acoustic method and the visual method were similar for the water-1-butanol mixture; however, the time estimated by the acoustic method was longer when compared with that estimated by the visual method for the water-ethanol mixture due to the residual ethanol at the bottom of the droplet
|
650 |
|
4 |
|a Journal Article
|
650 |
|
4 |
|a Research Support, Non-U.S. Gov't
|
700 |
1 |
|
|a Toubal, Malika
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Carlier, Julien
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Harmand, Souad
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Nongaillard, Bertrand
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Bigerelle, Maxence
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Langmuir : the ACS journal of surfaces and colloids
|d 1992
|g 32(2016), 38 vom: 27. Sept., Seite 9836-45
|w (DE-627)NLM098181009
|x 1520-5827
|7 nnns
|
773 |
1 |
8 |
|g volume:32
|g year:2016
|g number:38
|g day:27
|g month:09
|g pages:9836-45
|
856 |
4 |
0 |
|u http://dx.doi.org/10.1021/acs.langmuir.6b02564
|3 Volltext
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_22
|
912 |
|
|
|a GBV_ILN_350
|
912 |
|
|
|a GBV_ILN_721
|
951 |
|
|
|a AR
|
952 |
|
|
|d 32
|j 2016
|e 38
|b 27
|c 09
|h 9836-45
|