Interfibrillar packing of bovine cornea by table-top and synchrotron scanning SAXS microscopy

Bovine cornea was studied with scanning small-angle X-ray scattering (SAXS) microscopy, by using both synchrotron radiation and a microfocus laboratory source. A combination of statistical (adaptive binning and canonical correlation analysis) and crystallographic (pair distribution function analysis...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of applied crystallography. - 1998. - 49(2016), Pt 4 vom: 01. Aug., Seite 1231-1239
1. Verfasser: Sibillano, T (VerfasserIn)
Weitere Verfasser: De Caro, L, Scattarella, F, Scarcelli, G, Siliqi, D, Altamura, D, Liebi, M, Ladisa, M, Bunk, O, Giannini, C
Format: Aufsatz
Sprache:English
Veröffentlicht: 2016
Zugriff auf das übergeordnete Werk:Journal of applied crystallography
Schlagworte:Journal Article bovine cornea scanning SAXS microscopy small-angle X-ray scattering
LEADER 01000caa a22002652 4500
001 NLM263247252
003 DE-627
005 20250220124059.0
007 tu
008 231224s2016 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0877.xml 
035 |a (DE-627)NLM263247252 
035 |a (NLM)27504077 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Sibillano, T  |e verfasserin  |4 aut 
245 1 0 |a Interfibrillar packing of bovine cornea by table-top and synchrotron scanning SAXS microscopy 
264 1 |c 2016 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Revised 25.03.2024 
500 |a published: Electronic-eCollection 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Bovine cornea was studied with scanning small-angle X-ray scattering (SAXS) microscopy, by using both synchrotron radiation and a microfocus laboratory source. A combination of statistical (adaptive binning and canonical correlation analysis) and crystallographic (pair distribution function analysis) approaches allowed inspection of the collagen lateral packing of the supramolecular structure. Results reveal (i) a decrease of the interfibrillar distance and of the shell thickness around the fibrils from the periphery to the center of the cornea, (ii) a uniform fibril diameter across the explored area, and (iii) a distorted quasi-hexagonal arrangement of the collagen fibrils. The results are in agreement with existing literature. The overlap between laboratory and synchrotron-radiation data opens new perspectives for further studies on collagen-based/engineered tissues by the SAXS microscopy technique at laboratory-scale facilities 
650 4 |a Journal Article 
650 4 |a bovine cornea 
650 4 |a scanning SAXS microscopy 
650 4 |a small-angle X-ray scattering 
700 1 |a De Caro, L  |e verfasserin  |4 aut 
700 1 |a Scattarella, F  |e verfasserin  |4 aut 
700 1 |a Scarcelli, G  |e verfasserin  |4 aut 
700 1 |a Siliqi, D  |e verfasserin  |4 aut 
700 1 |a Altamura, D  |e verfasserin  |4 aut 
700 1 |a Liebi, M  |e verfasserin  |4 aut 
700 1 |a Ladisa, M  |e verfasserin  |4 aut 
700 1 |a Bunk, O  |e verfasserin  |4 aut 
700 1 |a Giannini, C  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of applied crystallography  |d 1998  |g 49(2016), Pt 4 vom: 01. Aug., Seite 1231-1239  |w (DE-627)NLM098121561  |x 0021-8898  |7 nnns 
773 1 8 |g volume:49  |g year:2016  |g number:Pt 4  |g day:01  |g month:08  |g pages:1231-1239 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 49  |j 2016  |e Pt 4  |b 01  |c 08  |h 1231-1239