Limitations of the removal of cyanide from coking wastewater by ozonation and by the hydrogen peroxide-ozone process
The purpose of this study is to compare the efficiency of ozonation and the hydrogen peroxide-ozone process for the removal of cyanide from coking wastewater. The most efficient oxidation process is combined with coagulation-flocculation-decantation and lime-soda ash softening pretreatments. The oxi...
Veröffentlicht in: | Water science and technology : a journal of the International Association on Water Pollution Research. - 1986. - 74(2016), 2 vom: 01., Seite 482-90 |
---|---|
1. Verfasser: | |
Weitere Verfasser: | , , |
Format: | Online-Aufsatz |
Sprache: | English |
Veröffentlicht: |
2016
|
Zugriff auf das übergeordnete Werk: | Water science and technology : a journal of the International Association on Water Pollution Research |
Schlagworte: | Comparative Study Journal Article Coke Cyanides Industrial Waste Waste Water Water Pollutants, Chemical Ozone 66H7ZZK23N Hydrogen Peroxide |