Undulator beamline optimization with integrated chicanes for X-ray free-electron-laser facilities

An optimization of the undulator layout of X-ray free-electron-laser (FEL) facilities based on placing small chicanes between the undulator modules is presented. The installation of magnetic chicanes offers the following benefits with respect to state-of-the-art FEL facilities: reduction of the requ...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 23(2016), Pt 4 vom: 25. Juli, Seite 861-8
1. Verfasser: Prat, Eduard (VerfasserIn)
Weitere Verfasser: Calvi, Marco, Ganter, Romain, Reiche, Sven, Schietinger, Thomas, Schmidt, Thomas
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2016
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article free-electron laser simulations undulator beamline design
LEADER 01000caa a22002652 4500
001 NLM261902709
003 DE-627
005 20250220082833.0
007 cr uuu---uuuuu
008 231224s2016 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577516007165  |2 doi 
028 5 2 |a pubmed25n0872.xml 
035 |a (DE-627)NLM261902709 
035 |a (NLM)27359133 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Prat, Eduard  |e verfasserin  |4 aut 
245 1 0 |a Undulator beamline optimization with integrated chicanes for X-ray free-electron-laser facilities 
264 1 |c 2016 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 20.08.2018 
500 |a Date Revised 20.08.2018 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a An optimization of the undulator layout of X-ray free-electron-laser (FEL) facilities based on placing small chicanes between the undulator modules is presented. The installation of magnetic chicanes offers the following benefits with respect to state-of-the-art FEL facilities: reduction of the required undulator length to achieve FEL saturation, improvement of the longitudinal coherence of the FEL pulses, and the ability to produce shorter FEL pulses with higher power levels. Numerical simulations performed for the soft X-ray beamline of the SwissFEL facility show that optimizing the advantages of the layout requires shorter undulator modules than the standard ones. This proposal allows a very compact undulator beamline that produces fully coherent FEL pulses and it makes possible new kinds of experiments that require very short and high-power FEL pulses 
650 4 |a Journal Article 
650 4 |a free-electron laser 
650 4 |a simulations 
650 4 |a undulator beamline design 
700 1 |a Calvi, Marco  |e verfasserin  |4 aut 
700 1 |a Ganter, Romain  |e verfasserin  |4 aut 
700 1 |a Reiche, Sven  |e verfasserin  |4 aut 
700 1 |a Schietinger, Thomas  |e verfasserin  |4 aut 
700 1 |a Schmidt, Thomas  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 23(2016), Pt 4 vom: 25. Juli, Seite 861-8  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:23  |g year:2016  |g number:Pt 4  |g day:25  |g month:07  |g pages:861-8 
856 4 0 |u http://dx.doi.org/10.1107/S1600577516007165  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 23  |j 2016  |e Pt 4  |b 25  |c 07  |h 861-8