Open-Ended Coaxial Dielectric Probe Effective Penetration Depth Determination

We have performed a series of experiments which demonstrate the effect of open-ended coaxial diameter on the depth of penetration. We used a two layer configuration of a liquid and movable cylindrical piece of either Teflon or acrylic. The technique accurately demonstrates the depth in a sample for...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on microwave theory and techniques. - 1998. - 64(2016), 3 vom: 01. März, Seite 915-923
1. Verfasser: Meaney, Paul M (VerfasserIn)
Weitere Verfasser: Gregory, Andrew P, Seppälä, Jan, Lahtinen, Tapani
Format: Aufsatz
Sprache:English
Veröffentlicht: 2016
Zugriff auf das übergeordnete Werk:IEEE transactions on microwave theory and techniques
Schlagworte:Journal Article Dielectric open-ended coaxial probe penetration depth probe diameter tissue properties
LEADER 01000naa a22002652 4500
001 NLM261786059
003 DE-627
005 20231224200318.0
007 tu
008 231224s2016 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0872.xml 
035 |a (DE-627)NLM261786059 
035 |a (NLM)27346890 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Meaney, Paul M  |e verfasserin  |4 aut 
245 1 0 |a Open-Ended Coaxial Dielectric Probe Effective Penetration Depth Determination 
264 1 |c 2016 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Revised 21.03.2022 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a We have performed a series of experiments which demonstrate the effect of open-ended coaxial diameter on the depth of penetration. We used a two layer configuration of a liquid and movable cylindrical piece of either Teflon or acrylic. The technique accurately demonstrates the depth in a sample for which a given probe diameter provides a reasonable measure of the bulk dielectric properties for a heterogeneous volume. In addition we have developed a technique for determining the effective depth for a given probe diameter size. Using a set of simulations mimicking four 50 Ω coaxial cable diameters, we demonstrate that the penetration depth in both water and saline has a clear dependence on probe diameter but is remarkably uniform over frequency and with respect to the intervening liquid permittivity. Two different 50 Ω commercial probes were similarly tested and confirm these observations. This result has significant implications to a range of dielectric measurements, most notably in the area of tissue property studies 
650 4 |a Journal Article 
650 4 |a Dielectric 
650 4 |a open-ended coaxial probe 
650 4 |a penetration depth 
650 4 |a probe diameter 
650 4 |a tissue properties 
700 1 |a Gregory, Andrew P  |e verfasserin  |4 aut 
700 1 |a Seppälä, Jan  |e verfasserin  |4 aut 
700 1 |a Lahtinen, Tapani  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on microwave theory and techniques  |d 1998  |g 64(2016), 3 vom: 01. März, Seite 915-923  |w (DE-627)NLM098148141  |x 0018-9480  |7 nnns 
773 1 8 |g volume:64  |g year:2016  |g number:3  |g day:01  |g month:03  |g pages:915-923 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 64  |j 2016  |e 3  |b 01  |c 03  |h 915-923