Electrochemically Induced Nanobubbles between Graphene and Mica

We present a new method to create dynamic nanobubbles. The nanobubbles are created between graphene and mica by reducing intercalated water to hydrogen. The nanobubbles have a typical radius of several hundred nanometers, a height of a few tens of nanometers and an internal pressure in the range of...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Langmuir : the ACS journal of surfaces and colloids. - 1985. - 32(2016), 26 vom: 05. Juli, Seite 6582-90
1. Verfasser: Dollekamp, Edwin (VerfasserIn)
Weitere Verfasser: Bampoulis, Pantelis, Poelsema, Bene, Zandvliet, Harold J W, Kooij, E Stefan
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2016
Zugriff auf das übergeordnete Werk:Langmuir : the ACS journal of surfaces and colloids
Schlagworte:Journal Article Research Support, Non-U.S. Gov't
LEADER 01000caa a22002652 4500
001 NLM261177974
003 DE-627
005 20250220062517.0
007 cr uuu---uuuuu
008 231224s2016 xx |||||o 00| ||eng c
024 7 |a 10.1021/acs.langmuir.6b00777  |2 doi 
028 5 2 |a pubmed25n0870.xml 
035 |a (DE-627)NLM261177974 
035 |a (NLM)27275663 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Dollekamp, Edwin  |e verfasserin  |4 aut 
245 1 0 |a Electrochemically Induced Nanobubbles between Graphene and Mica 
264 1 |c 2016 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 30.05.2018 
500 |a Date Revised 30.05.2018 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a We present a new method to create dynamic nanobubbles. The nanobubbles are created between graphene and mica by reducing intercalated water to hydrogen. The nanobubbles have a typical radius of several hundred nanometers, a height of a few tens of nanometers and an internal pressure in the range of 0.5-8 MPa. Our approach paves the way to the realization of nanobubbles of which both size and internal pressure are tunable 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Bampoulis, Pantelis  |e verfasserin  |4 aut 
700 1 |a Poelsema, Bene  |e verfasserin  |4 aut 
700 1 |a Zandvliet, Harold J W  |e verfasserin  |4 aut 
700 1 |a Kooij, E Stefan  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Langmuir : the ACS journal of surfaces and colloids  |d 1985  |g 32(2016), 26 vom: 05. Juli, Seite 6582-90  |w (DE-627)NLM098181009  |x 1520-5827  |7 nnns 
773 1 8 |g volume:32  |g year:2016  |g number:26  |g day:05  |g month:07  |g pages:6582-90 