Accuracy in Rietveld quantitative phase analysis : a comparative study of strictly monochromatic Mo and Cu radiations

This study reports 78 Rietveld quantitative phase analyses using Cu Kα1, Mo Kα1 and synchrotron radiations. Synchrotron powder diffraction has been used to validate the most challenging analyses. From the results for three series with increasing contents of an analyte (an inorganic crystalline phase...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of applied crystallography. - 1998. - 49(2016), Pt 3 vom: 01. Juni, Seite 722-735
1. Verfasser: León-Reina, L (VerfasserIn)
Weitere Verfasser: García-Maté, M, Álvarez-Pinazo, G, Santacruz, I, Vallcorba, O, De la Torre, A G, Aranda, M A G
Format: Aufsatz
Sprache:English
Veröffentlicht: 2016
Zugriff auf das übergeordnete Werk:Journal of applied crystallography
Schlagworte:Journal Article high-energy laboratory X-ray powder diffraction limit of quantification spiking method
LEADER 01000caa a22002652 4500
001 NLM261173162
003 DE-627
005 20250220062430.0
007 tu
008 231224s2016 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0870.xml 
035 |a (DE-627)NLM261173162 
035 |a (NLM)27275132 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a León-Reina, L  |e verfasserin  |4 aut 
245 1 0 |a Accuracy in Rietveld quantitative phase analysis  |b a comparative study of strictly monochromatic Mo and Cu radiations 
264 1 |c 2016 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Revised 29.09.2020 
500 |a published: Electronic-eCollection 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a This study reports 78 Rietveld quantitative phase analyses using Cu Kα1, Mo Kα1 and synchrotron radiations. Synchrotron powder diffraction has been used to validate the most challenging analyses. From the results for three series with increasing contents of an analyte (an inorganic crystalline phase, an organic crystalline phase and a glass), it is inferred that Rietveld analyses from high-energy Mo Kα1 radiation have slightly better accuracies than those obtained from Cu Kα1 radiation. This behaviour has been established from the results of the calibration graphics obtained through the spiking method and also from Kullback-Leibler distance statistic studies. This outcome is explained, in spite of the lower diffraction power for Mo radiation when compared to Cu radiation, as arising because of the larger volume tested with Mo and also because higher energy allows one to record patterns with fewer systematic errors. The limit of detection (LoD) and limit of quantification (LoQ) have also been established for the studied series. For similar recording times, the LoDs in Cu patterns, ∼0.2 wt%, are slightly lower than those derived from Mo patterns, ∼0.3 wt%. The LoQ for a well crystallized inorganic phase using laboratory powder diffraction was established to be close to 0.10 wt% in stable fits with good precision. However, the accuracy of these analyses was poor with relative errors near to 100%. Only contents higher than 1.0 wt% yielded analyses with relative errors lower than 20% 
650 4 |a Journal Article 
650 4 |a high-energy laboratory X-ray powder diffraction 
650 4 |a limit of quantification 
650 4 |a spiking method 
700 1 |a García-Maté, M  |e verfasserin  |4 aut 
700 1 |a Álvarez-Pinazo, G  |e verfasserin  |4 aut 
700 1 |a Santacruz, I  |e verfasserin  |4 aut 
700 1 |a Vallcorba, O  |e verfasserin  |4 aut 
700 1 |a De la Torre, A G  |e verfasserin  |4 aut 
700 1 |a Aranda, M A G  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of applied crystallography  |d 1998  |g 49(2016), Pt 3 vom: 01. Juni, Seite 722-735  |w (DE-627)NLM098121561  |x 0021-8898  |7 nnns 
773 1 8 |g volume:49  |g year:2016  |g number:Pt 3  |g day:01  |g month:06  |g pages:722-735 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 49  |j 2016  |e Pt 3  |b 01  |c 06  |h 722-735