Capacitive micromachined ultrasonic transducers (cMUTs) provide promising ultrasonic technology that could become an alternative to piezoelectric probes for medical applications. cMUTs could be very valuable for contrast-enhanced ultrasound imaging based on higher harmonics detection. However, their...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 63(2016), 10 vom: 17. Okt., Seite 1496-1504
1. Verfasser: Fouan, Damien (VerfasserIn)
Weitere Verfasser: Bouakaz, Ayache
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2016
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article Research Support, Non-U.S. Gov't
LEADER 01000naa a22002652 4500
001 NLM260427292
003 DE-627
005 20231224193400.0
007 cr uuu---uuuuu
008 231224s2016 xx |||||o 00| ||eng c
028 5 2 |a pubmed24n0868.xml 
035 |a (DE-627)NLM260427292 
035 |a (NLM)27187953 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Fouan, Damien  |e verfasserin  |4 aut 
245 1 0 |a Investigation of Classical Pulse Sequences for Contrast-Enhanced Ultrasound Imaging With a cMUT Probe 
264 1 |c 2016 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 19.07.2018 
500 |a Date Revised 19.07.2018 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Capacitive micromachined ultrasonic transducers (cMUTs) provide promising ultrasonic technology that could become an alternative to piezoelectric probes for medical applications. cMUTs could be very valuable for contrast-enhanced ultrasound imaging based on higher harmonics detection. However, their use is restricted by the intrinsic nonlinearity of the cMUT transmitters themselves, because it is difficult to distinguish between the nonlinearity of the microbubbles and the nonlinearity arising from the emitting transducer. A number of approaches have been proposed in recent years to cancel the nonlinearity of cMUTs. However, these techniques have limitations in terms of implementation with current ultrasound scanner electronics. The solution to be comparable with classical methods should not need precharacterization of the probe or changing the bias voltage (amplitude or polarity) but does need good sensitivity and a high frame rate to avoid motion artifacts. We propose here proof of a concept of an adapted amplitude modulation sequence with cMUT where transmit elements operate alternately. We show that this method, which is currently used with piezoelectric probes, is fully applicable to cMUT probes and the intrinsic nonlinearity of the transmitter is no longer an issue 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Bouakaz, Ayache  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 63(2016), 10 vom: 17. Okt., Seite 1496-1504  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 