Conventional heating vs. microwave sludge pretreatment comparison under identical heating/cooling profiles for thermophilic advanced anaerobic digestion

Copyright © 2016 Elsevier Ltd. All rights reserved.

Bibliographische Detailangaben
Veröffentlicht in:Waste management (New York, N.Y.). - 1999. - 53(2016) vom: 26. Juli, Seite 182-95
1. Verfasser: Hosseini Koupaie, E (VerfasserIn)
Weitere Verfasser: Eskicioglu, C
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2016
Zugriff auf das übergeordnete Werk:Waste management (New York, N.Y.)
Schlagworte:Journal Article Biogas Conventional heating Microwave hydrolysis Sludge pretreatment Solubilization Thermophilic anaerobic digestion Sewage
Beschreibung
Zusammenfassung:Copyright © 2016 Elsevier Ltd. All rights reserved.
This research evaluates whether there is any advantage of selecting one of the thermal methods of sludge pretreatment, conventional heating (CH) and microwave hydrolysis (MW), over another to enhance municipal sludge disintegration and performance of thermophilic anaerobic digestion (AD). For this purpose, a custom-built CH system simulating MW hydrolysis under identical heating and cooling profiles was used. The effects of three main pretreatment parameters including pretreatment method (CH and MW), heating ramp rate (3, 6 and 11°C/min) and final temperature (80, 120 and 160°C) on sludge solubilization and performance of thermophilic batch AD were evaluated. The effects of CH and MW hydrolysis were observed to be similar for sludge disintegration and digester performance (p-value>0.05), while the effects of final temperature and heating ramp rate were proven to be different (p-value<0.05). According to the results, it is essential to apply MW and CH pretreatments under identical experimental condition for an unbiased comparison which supports the findings of the author's earlier study under mesophilic condition. Failing to address this issue explains the significant inconsistency observed among the findings of the previous CH vs. MW comparison studies that were unable to implement identical thermal profiles (between CH and MW) during sludge pretreatment. In comparison with mesophilic AD, thermophilic AD revealed lower biodegradation rate constant at the highest pretreatment temperature tested (160°C), suggesting its higher sensitivity to the inhibitory effects of thermal pretreatment at the elevated temperatures
Beschreibung:Date Completed 14.02.2018
Date Revised 14.02.2018
published: Print-Electronic
Citation Status MEDLINE
ISSN:1879-2456
DOI:10.1016/j.wasman.2016.04.014