Effects of Confinement on the Dielectric Response of Water Extends up to Mesoscale Dimensions

The extent of confinement effects on water is not clear in the literature. While some properties are affected only within a few nanometers from the wall surface, others are affected over long length scales, but the range is not clear. In this work, we have examined the dielectric response of confine...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Langmuir : the ACS journal of surfaces and colloids. - 1992. - 32(2016), 19 vom: 17. Mai, Seite 4765-73
1. Verfasser: De Luca, Sergio (VerfasserIn)
Weitere Verfasser: Kannam, Sridhar Kumar, Todd, B D, Frascoli, Federico, Hansen, J S, Daivis, Peter J
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2016
Zugriff auf das übergeordnete Werk:Langmuir : the ACS journal of surfaces and colloids
Schlagworte:Journal Article Research Support, Non-U.S. Gov't
LEADER 01000naa a22002652 4500
001 NLM259750573
003 DE-627
005 20231224191858.0
007 cr uuu---uuuuu
008 231224s2016 xx |||||o 00| ||eng c
024 7 |a 10.1021/acs.langmuir.6b00791  |2 doi 
028 5 2 |a pubmed24n0865.xml 
035 |a (DE-627)NLM259750573 
035 |a (NLM)27115841 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a De Luca, Sergio  |e verfasserin  |4 aut 
245 1 0 |a Effects of Confinement on the Dielectric Response of Water Extends up to Mesoscale Dimensions 
264 1 |c 2016 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 18.05.2018 
500 |a Date Revised 18.05.2018 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a The extent of confinement effects on water is not clear in the literature. While some properties are affected only within a few nanometers from the wall surface, others are affected over long length scales, but the range is not clear. In this work, we have examined the dielectric response of confined water under the influence of external electric fields along with the dipolar fluctuations at equilibrium. The confinement induces a strong anisotropic effect which is evident up to 100 nm channel width, and may extend to macroscopic dimensions. The root-mean-square fluctuations of the total orientational dipole moment in the direction perpendicular to the surfaces is 1 order of magnitude smaller than the value attained in the parallel direction and is independent of the channel width. Consequently, the isotropic condition is unlikely to be recovered until the channel width reaches macroscopic dimensions. Consistent with dipole moment fluctuations, the effect of confinement on the dielectric response also persists up to channel widths considerably beyond 100 nm. When an electric field is applied in the perpendicular direction, the orientational relaxation is 3 orders of magnitude faster than the dipolar relaxation in the parallel direction and independent of temperature 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Kannam, Sridhar Kumar  |e verfasserin  |4 aut 
700 1 |a Todd, B D  |e verfasserin  |4 aut 
700 1 |a Frascoli, Federico  |e verfasserin  |4 aut 
700 1 |a Hansen, J S  |e verfasserin  |4 aut 
700 1 |a Daivis, Peter J  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Langmuir : the ACS journal of surfaces and colloids  |d 1992  |g 32(2016), 19 vom: 17. Mai, Seite 4765-73  |w (DE-627)NLM098181009  |x 1520-5827  |7 nnns 
773 1 8 |g volume:32  |g year:2016  |g number:19  |g day:17  |g month:05  |g pages:4765-73 
856 4 0 |u http://dx.doi.org/10.1021/acs.langmuir.6b00791  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_350 
912 |a GBV_ILN_721 
951 |a AR 
952 |d 32  |j 2016  |e 19  |b 17  |c 05  |h 4765-73