LEADER |
01000naa a22002652 4500 |
001 |
NLM259166197 |
003 |
DE-627 |
005 |
20231224190610.0 |
007 |
cr uuu---uuuuu |
008 |
231224s2016 xx |||||o 00| ||eng c |
024 |
7 |
|
|a 10.1016/j.jsha.2015.06.007
|2 doi
|
028 |
5 |
2 |
|a pubmed24n0863.xml
|
035 |
|
|
|a (DE-627)NLM259166197
|
035 |
|
|
|a (NLM)27053899
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Ali, Safaa
|e verfasserin
|4 aut
|
245 |
1 |
0 |
|a Transcatheter closure of patent ductus arteriosus in children weighing 10 kg or less
|b Initial experience at Sohag University Hospital
|
264 |
|
1 |
|c 2016
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
500 |
|
|
|a Date Completed 07.04.2016
|
500 |
|
|
|a Date Revised 30.09.2020
|
500 |
|
|
|a published: Print-Electronic
|
500 |
|
|
|a Citation Status PubMed-not-MEDLINE
|
520 |
|
|
|a AIM: To assess the challenges, feasibility, and efficacy of device closure of patent ductus arteriosus (PDA) in small children weighing ⩽10 kg for different types of devices used in an initial experience at Sohag University hospital
|
520 |
|
|
|a METHODS: Between March 2011 and September 2014, 91 patients with PDA underwent transcatheter closure in our institute, among whom 54 weighed ⩽10 kg. All of these patients underwent transcatheter closure of PDA using either a Cook Detachable Coil, PFM Nit-Occlud, or Amplatzer duct occluder. A retrospective review of the treatment results and adverse events was performed
|
520 |
|
|
|a RESULTS: Successful device placement was achieved in 53/54 small children (98.1%). The median minimum PDA diameter was 2.4 mm [interquartile range (IQR, 1.8-3.5 mm), median weight 8 kg (IQR, 7-10 kg), and median age 10 months (IQR, 8-17 months)]. Mild aortic obstruction occurred in one case (1.9%), as the device became displaced towards the aorta after release. The device embolized in one case (1.9%) and no retrieval attempt was made. Five cases (9.3%) had minor vascular complications
|
520 |
|
|
|a CONCLUSION: With the current availability of devices for PDA closure, transcatheter closure of PDA is considered safe and efficacious in small children weighing ⩽10 kg with good mid-term outcome. The procedure had a low rate of high-severity adverse events even with the initial experience of the catheterization laboratory
|
650 |
|
4 |
|a Journal Article
|
650 |
|
4 |
|a Adverse events
|
650 |
|
4 |
|a Closure
|
650 |
|
4 |
|a Device
|
650 |
|
4 |
|a Patent ductus arteriosus
|
700 |
1 |
|
|a El Sisi, Amel
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Journal of the Saudi Heart Association
|d 1999
|g 28(2016), 2 vom: 15. Apr., Seite 95-100
|w (DE-627)NLM098225227
|x 1016-7315
|7 nnns
|
773 |
1 |
8 |
|g volume:28
|g year:2016
|g number:2
|g day:15
|g month:04
|g pages:95-100
|
856 |
4 |
0 |
|u http://dx.doi.org/10.1016/j.jsha.2015.06.007
|3 Volltext
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_350
|
951 |
|
|
|a AR
|
952 |
|
|
|d 28
|j 2016
|e 2
|b 15
|c 04
|h 95-100
|