Transcatheter closure of patent ductus arteriosus in children weighing 10 kg or less : Initial experience at Sohag University Hospital

AIM: To assess the challenges, feasibility, and efficacy of device closure of patent ductus arteriosus (PDA) in small children weighing ⩽10 kg for different types of devices used in an initial experience at Sohag University hospital

Bibliographische Detailangaben
Veröffentlicht in:Journal of the Saudi Heart Association. - 1999. - 28(2016), 2 vom: 15. Apr., Seite 95-100
1. Verfasser: Ali, Safaa (VerfasserIn)
Weitere Verfasser: El Sisi, Amel
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2016
Zugriff auf das übergeordnete Werk:Journal of the Saudi Heart Association
Schlagworte:Journal Article Adverse events Closure Device Patent ductus arteriosus
LEADER 01000naa a22002652 4500
001 NLM259166197
003 DE-627
005 20231224190610.0
007 cr uuu---uuuuu
008 231224s2016 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jsha.2015.06.007  |2 doi 
028 5 2 |a pubmed24n0863.xml 
035 |a (DE-627)NLM259166197 
035 |a (NLM)27053899 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Ali, Safaa  |e verfasserin  |4 aut 
245 1 0 |a Transcatheter closure of patent ductus arteriosus in children weighing 10 kg or less  |b Initial experience at Sohag University Hospital 
264 1 |c 2016 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 07.04.2016 
500 |a Date Revised 30.09.2020 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a AIM: To assess the challenges, feasibility, and efficacy of device closure of patent ductus arteriosus (PDA) in small children weighing ⩽10 kg for different types of devices used in an initial experience at Sohag University hospital 
520 |a METHODS: Between March 2011 and September 2014, 91 patients with PDA underwent transcatheter closure in our institute, among whom 54 weighed ⩽10 kg. All of these patients underwent transcatheter closure of PDA using either a Cook Detachable Coil, PFM Nit-Occlud, or Amplatzer duct occluder. A retrospective review of the treatment results and adverse events was performed 
520 |a RESULTS: Successful device placement was achieved in 53/54 small children (98.1%). The median minimum PDA diameter was 2.4 mm [interquartile range (IQR, 1.8-3.5 mm), median weight 8 kg (IQR, 7-10 kg), and median age 10 months (IQR, 8-17 months)]. Mild aortic obstruction occurred in one case (1.9%), as the device became displaced towards the aorta after release. The device embolized in one case (1.9%) and no retrieval attempt was made. Five cases (9.3%) had minor vascular complications 
520 |a CONCLUSION: With the current availability of devices for PDA closure, transcatheter closure of PDA is considered safe and efficacious in small children weighing ⩽10 kg with good mid-term outcome. The procedure had a low rate of high-severity adverse events even with the initial experience of the catheterization laboratory 
650 4 |a Journal Article 
650 4 |a Adverse events 
650 4 |a Closure 
650 4 |a Device 
650 4 |a Patent ductus arteriosus 
700 1 |a El Sisi, Amel  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of the Saudi Heart Association  |d 1999  |g 28(2016), 2 vom: 15. Apr., Seite 95-100  |w (DE-627)NLM098225227  |x 1016-7315  |7 nnns 
773 1 8 |g volume:28  |g year:2016  |g number:2  |g day:15  |g month:04  |g pages:95-100 
856 4 0 |u http://dx.doi.org/10.1016/j.jsha.2015.06.007  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 28  |j 2016  |e 2  |b 15  |c 04  |h 95-100