Analysis and control of the photon beam position at PLS-II

At third-generation light sources, the photon beam position stability is a critical issue for user experiments. In general, photon beam position monitors are developed to detect the real photon beam position, and the position is controlled by a feedback system in order to maintain the reference phot...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 23(2016), 2 vom: 01. März, Seite 448-54
1. Verfasser: Ko, J (VerfasserIn)
Weitere Verfasser: Kim, I-Y, Kim, C, Kim, D-T, Huang, J-Y, Shin, S
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2016
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Research Support, Non-U.S. Gov't SVD analysis photon beam position monitor stability
LEADER 01000caa a22002652 4500
001 NLM257861963
003 DE-627
005 20250219184813.0
007 cr uuu---uuuuu
008 231224s2016 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577516001338  |2 doi 
028 5 2 |a pubmed25n0859.xml 
035 |a (DE-627)NLM257861963 
035 |a (NLM)26917132 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Ko, J  |e verfasserin  |4 aut 
245 1 0 |a Analysis and control of the photon beam position at PLS-II 
264 1 |c 2016 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 24.06.2016 
500 |a Date Revised 24.05.2024 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a At third-generation light sources, the photon beam position stability is a critical issue for user experiments. In general, photon beam position monitors are developed to detect the real photon beam position, and the position is controlled by a feedback system in order to maintain the reference photon beam position. At Pohang Light Source II, a photon beam position stability of less than 1 µm r.m.s. was achieved for a user service period in the beamline, where the photon beam position monitor is installed. Nevertheless, a detailed analysis of the photon beam position data was necessary in order to ensure the performance of the photon beam position monitor, since it can suffer from various unknown types of noise, such as background contamination due to upstream or downstream dipole radiation, and undulator gap dependence. This paper reports the results of a start-to-end study of the photon beam position stability and a singular value decomposition analysis to confirm the reliability of the photon beam position data 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 4 |a SVD analysis 
650 4 |a photon beam position monitor 
650 4 |a stability 
700 1 |a Kim, I-Y  |e verfasserin  |4 aut 
700 1 |a Kim, C  |e verfasserin  |4 aut 
700 1 |a Kim, D-T  |e verfasserin  |4 aut 
700 1 |a Huang, J-Y  |e verfasserin  |4 aut 
700 1 |a Shin, S  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 23(2016), 2 vom: 01. März, Seite 448-54  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:23  |g year:2016  |g number:2  |g day:01  |g month:03  |g pages:448-54 