|
|
|
|
LEADER |
01000caa a22002652c 4500 |
001 |
NLM257861882 |
003 |
DE-627 |
005 |
20250219184813.0 |
007 |
cr uuu---uuuuu |
008 |
231224s2016 xx |||||o 00| ||eng c |
024 |
7 |
|
|a 10.1107/S1600577515022754
|2 doi
|
028 |
5 |
2 |
|a pubmed25n0859.xml
|
035 |
|
|
|a (DE-627)NLM257861882
|
035 |
|
|
|a (NLM)26917125
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Philipp, Hugh T
|e verfasserin
|4 aut
|
245 |
1 |
0 |
|a High-speed X-ray imaging pixel array detector for synchrotron bunch isolation
|
264 |
|
1 |
|c 2016
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
500 |
|
|
|a Date Completed 13.12.2016
|
500 |
|
|
|a Date Revised 24.05.2024
|
500 |
|
|
|a published: Print-Electronic
|
500 |
|
|
|a Citation Status MEDLINE
|
520 |
|
|
|a A wide-dynamic-range imaging X-ray detector designed for recording successive frames at rates up to 10 MHz is described. X-ray imaging with frame rates of up to 6.5 MHz have been experimentally verified. The pixel design allows for up to 8-12 frames to be stored internally at high speed before readout, which occurs at a 1 kHz frame rate. An additional mode of operation allows the integration capacitors to be re-addressed repeatedly before readout which can enhance the signal-to-noise ratio of cyclical processes. This detector, along with modern storage ring sources which provide short (10-100 ps) and intense X-ray pulses at megahertz rates, opens new avenues for the study of rapid structural changes in materials. The detector consists of hybridized modules, each of which is comprised of a 500 µm-thick silicon X-ray sensor solder bump-bonded, pixel by pixel, to an application-specific integrated circuit. The format of each module is 128 × 128 pixels with a pixel pitch of 150 µm. In the prototype detector described here, the three-side buttable modules are tiled in a 3 × 2 array with a full format of 256 × 384 pixels. The characteristics, operation, testing and application of the detector are detailed
|
650 |
|
4 |
|a Journal Article
|
650 |
|
4 |
|a Research Support, N.I.H., Extramural
|
650 |
|
4 |
|a Research Support, Non-U.S. Gov't
|
650 |
|
4 |
|a Research Support, U.S. Gov't, Non-P.H.S.
|
650 |
|
4 |
|a X-ray detector
|
650 |
|
4 |
|a area detector
|
650 |
|
4 |
|a high frame rate
|
650 |
|
4 |
|a imaging detector
|
650 |
|
4 |
|a pixel array detectors
|
650 |
|
4 |
|a time-resolved imaging
|
700 |
1 |
|
|a Tate, Mark W
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Purohit, Prafull
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Shanks, Katherine S
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Weiss, Joel T
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Gruner, Sol M
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Journal of synchrotron radiation
|d 1994
|g 23(2016), 2 vom: 01. März, Seite 395-403
|w (DE-627)NLM09824129X
|x 1600-5775
|7 nnas
|
773 |
1 |
8 |
|g volume:23
|g year:2016
|g number:2
|g day:01
|g month:03
|g pages:395-403
|
856 |
4 |
0 |
|u http://dx.doi.org/10.1107/S1600577515022754
|3 Volltext
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_40
|
912 |
|
|
|a GBV_ILN_350
|
912 |
|
|
|a GBV_ILN_2005
|
951 |
|
|
|a AR
|
952 |
|
|
|d 23
|j 2016
|e 2
|b 01
|c 03
|h 395-403
|