Comparison of two confocal micro-XRF spectrometers with different design aspects

Two different confocal micro X-ray fluorescence spectrometers have been developed and installed at Osaka City University and the Vienna University of Technology Atominstitut. The Osaka City University system is a high resolution spectrometer operating in air. The Vienna University of Technology Atom...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:X-ray spectrometry : XRS. - 1998. - 43(2014), 2 vom: 02. März, Seite 93-101
1. Verfasser: Smolek, S (VerfasserIn)
Weitere Verfasser: Nakazawa, T, Tabe, A, Nakano, K, Tsuji, K, Streli, C, Wobrauschek, P
Format: Aufsatz
Sprache:English
Veröffentlicht: 2014
Zugriff auf das übergeordnete Werk:X-ray spectrometry : XRS
Schlagworte:Journal Article
LEADER 01000caa a22002652 4500
001 NLM253329299
003 DE-627
005 20250219052326.0
007 tu
008 231224s2014 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0844.xml 
035 |a (DE-627)NLM253329299 
035 |a (NLM)26430286 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Smolek, S  |e verfasserin  |4 aut 
245 1 0 |a Comparison of two confocal micro-XRF spectrometers with different design aspects 
264 1 |c 2014 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Revised 11.11.2023 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Two different confocal micro X-ray fluorescence spectrometers have been developed and installed at Osaka City University and the Vienna University of Technology Atominstitut. The Osaka City University system is a high resolution spectrometer operating in air. The Vienna University of Technology Atominstitut spectrometer has a lower spatial resolution but is optimized for light element detection and operates under vacuum condition. The performance of both spectrometers was compared. In order to characterize the spatial resolution, a set of nine specially prepared single element thin film reference samples (500 nm in thickness, Al, Ti, Cr, Fe Ni, Cu, Zr, Mo, and Au) was used. Lower limits of detection were determined using the National Institute of Standards and Technology standard reference material glass standard 1412. A paint layer sample (cultural heritage application) and paint on automotive steel samples were analyzed with both instruments. The depth profile information was acquired by scanning the sample perpendicular to the surface. © 2013 The Authors. X-Ray Spectrometry published by John Wiley & Sons, Ltd 
650 4 |a Journal Article 
700 1 |a Nakazawa, T  |e verfasserin  |4 aut 
700 1 |a Tabe, A  |e verfasserin  |4 aut 
700 1 |a Nakano, K  |e verfasserin  |4 aut 
700 1 |a Tsuji, K  |e verfasserin  |4 aut 
700 1 |a Streli, C  |e verfasserin  |4 aut 
700 1 |a Wobrauschek, P  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t X-ray spectrometry : XRS  |d 1998  |g 43(2014), 2 vom: 02. März, Seite 93-101  |w (DE-627)NLM098127586  |x 0049-8246  |7 nnns 
773 1 8 |g volume:43  |g year:2014  |g number:2  |g day:02  |g month:03  |g pages:93-101 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 43  |j 2014  |e 2  |b 02  |c 03  |h 93-101