Subjective Evaluation of a Semi-Automatic Optical See-Through Head-Mounted Display Calibration Technique

With the growing availability of optical see-through (OST) head-mounted displays (HMDs) there is a present need for robust, uncomplicated, and automatic calibration methods suited for non-expert users. This work presents the results of a user study which both objectively and subjectively examines re...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on visualization and computer graphics. - 1996. - 21(2015), 4 vom: 10. Apr., Seite 491-500
1. Verfasser: Moser, Kenneth (VerfasserIn)
Weitere Verfasser: Itoh, Yuta, Oshima, Kohei, Swan, J Edward, Klinker, Gudrun, Sandor, Christian
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2015
Zugriff auf das übergeordnete Werk:IEEE transactions on visualization and computer graphics
Schlagworte:Journal Article Research Support, Non-U.S. Gov't Research Support, U.S. Gov't, Non-P.H.S.
LEADER 01000naa a22002652 4500
001 NLM252628411
003 DE-627
005 20231224164519.0
007 cr uuu---uuuuu
008 231224s2015 xx |||||o 00| ||eng c
024 7 |a 10.1109/TVCG.2015.2391856  |2 doi 
028 5 2 |a pubmed24n0842.xml 
035 |a (DE-627)NLM252628411 
035 |a (NLM)26357099 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Moser, Kenneth  |e verfasserin  |4 aut 
245 1 0 |a Subjective Evaluation of a Semi-Automatic Optical See-Through Head-Mounted Display Calibration Technique 
264 1 |c 2015 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 07.06.2016 
500 |a Date Revised 20.10.2017 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a With the growing availability of optical see-through (OST) head-mounted displays (HMDs) there is a present need for robust, uncomplicated, and automatic calibration methods suited for non-expert users. This work presents the results of a user study which both objectively and subjectively examines registration accuracy produced by three OST HMD calibration methods: (1) SPAAM, (2) Degraded SPAAM, and (3) Recycled INDICA, a recently developed semi-automatic calibration method. Accuracy metrics used for evaluation include subject provided quality values and error between perceived and absolute registration coordinates. Our results show all three calibration methods produce very accurate registration in the horizontal direction but caused subjects to perceive the distance of virtual objects to be closer than intended. Surprisingly, the semi-automatic calibration method produced more accurate registration vertically and in perceived object distance overall. User assessed quality values were also the highest for Recycled INDICA, particularly when objects were shown at distance. The results of this study confirm that Recycled INDICA is capable of producing equal or superior on-screen registration compared to common OST HMD calibration methods. We also identify a potential hazard in using reprojection error as a quantitative analysis technique to predict registration accuracy. We conclude with discussing the further need for examining INDICA calibration in binocular HMD systems, and the present possibility for creation of a closed-loop continuous calibration method for OST Augmented Reality 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 4 |a Research Support, U.S. Gov't, Non-P.H.S. 
700 1 |a Itoh, Yuta  |e verfasserin  |4 aut 
700 1 |a Oshima, Kohei  |e verfasserin  |4 aut 
700 1 |a Swan, J Edward  |e verfasserin  |4 aut 
700 1 |a Klinker, Gudrun  |e verfasserin  |4 aut 
700 1 |a Sandor, Christian  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on visualization and computer graphics  |d 1996  |g 21(2015), 4 vom: 10. Apr., Seite 491-500  |w (DE-627)NLM098269445  |x 1941-0506  |7 nnns 
773 1 8 |g volume:21  |g year:2015  |g number:4  |g day:10  |g month:04  |g pages:491-500 
856 4 0 |u http://dx.doi.org/10.1109/TVCG.2015.2391856  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 21  |j 2015  |e 4  |b 10  |c 04  |h 491-500