Towards a microchannel-based X-ray detector with two-dimensional spatial and time resolution and high dynamic range

X-ray detectors that combine two-dimensional spatial resolution with a high time resolution are needed in numerous applications of synchrotron radiation. Most detectors with this combination of capabilities are based on semiconductor technology and are therefore limited in size. Furthermore, the tim...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 22(2015), 5 vom: 20. Sept., Seite 1202-6
1. Verfasser: Adams, Bernhard W (VerfasserIn)
Weitere Verfasser: Mane, Anil U, Elam, Jeffrey W, Obaid, Razib, Wetstein, Matthew, Chollet, Matthieu
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2015
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Research Support, U.S. Gov't, Non-P.H.S. high dynamic range microchannel-based X-ray detector
LEADER 01000caa a22002652c 4500
001 NLM251986721
003 DE-627
005 20250219003031.0
007 cr uuu---uuuuu
008 231224s2015 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577515010322  |2 doi 
028 5 2 |a pubmed25n0839.xml 
035 |a (DE-627)NLM251986721 
035 |a (NLM)26289271 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Adams, Bernhard W  |e verfasserin  |4 aut 
245 1 0 |a Towards a microchannel-based X-ray detector with two-dimensional spatial and time resolution and high dynamic range 
264 1 |c 2015 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 29.10.2015 
500 |a Date Revised 20.08.2015 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a X-ray detectors that combine two-dimensional spatial resolution with a high time resolution are needed in numerous applications of synchrotron radiation. Most detectors with this combination of capabilities are based on semiconductor technology and are therefore limited in size. Furthermore, the time resolution is often realised through rapid time-gating of the acquisition, followed by a slower readout. Here, a detector technology is realised based on relatively inexpensive microchannel plates that uses GHz waveform sampling for a millimeter-scale spatial resolution and better than 100 ps time resolution. The technology is capable of continuous streaming of time- and location-tagged events at rates greater than 10(7) events per cm(2). Time-gating can be used for improved dynamic range 
650 4 |a Journal Article 
650 4 |a Research Support, U.S. Gov't, Non-P.H.S. 
650 4 |a high dynamic range 
650 4 |a microchannel-based X-ray detector 
700 1 |a Mane, Anil U  |e verfasserin  |4 aut 
700 1 |a Elam, Jeffrey W  |e verfasserin  |4 aut 
700 1 |a Obaid, Razib  |e verfasserin  |4 aut 
700 1 |a Wetstein, Matthew  |e verfasserin  |4 aut 
700 1 |a Chollet, Matthieu  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 22(2015), 5 vom: 20. Sept., Seite 1202-6  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnas 
773 1 8 |g volume:22  |g year:2015  |g number:5  |g day:20  |g month:09  |g pages:1202-6 
856 4 0 |u http://dx.doi.org/10.1107/S1600577515010322  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 22  |j 2015  |e 5  |b 20  |c 09  |h 1202-6