Influence of higher harmonics of the undulator in X-ray polarimetry and crystal monochromator design

The spectrum of the undulator radiation of beamline P01 at Petra III has been measured after passing a multiple reflection channel-cut polarimeter. Odd and even harmonics up to the 15th order, as well as Compton peaks which were produced by the high harmonics in the spectrum, could been measured. Th...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 22(2015), 5 vom: 20. Sept., Seite 1151-4
1. Verfasser: Marx-Glowna, Berit (VerfasserIn)
Weitere Verfasser: Schulze, Kai S, Uschmann, Ingo, Kämpfer, Tino, Weber, Günter, Hahn, Christoph, Wille, Hans Christian, Schlage, Kai, Röhlsberger, Ralf, Förster, Eckhart, Stöhlker, Thomas, Paulus, Gerhard G
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2015
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Research Support, Non-U.S. Gov't Compton scattering X-ray diffraction monochromator polarimetry undulator high harmonics
LEADER 01000naa a22002652 4500
001 NLM251986667
003 DE-627
005 20231224163155.0
007 cr uuu---uuuuu
008 231224s2015 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577515011510  |2 doi 
028 5 2 |a pubmed24n0840.xml 
035 |a (DE-627)NLM251986667 
035 |a (NLM)26289265 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Marx-Glowna, Berit  |e verfasserin  |4 aut 
245 1 0 |a Influence of higher harmonics of the undulator in X-ray polarimetry and crystal monochromator design 
264 1 |c 2015 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 29.10.2015 
500 |a Date Revised 20.08.2015 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a The spectrum of the undulator radiation of beamline P01 at Petra III has been measured after passing a multiple reflection channel-cut polarimeter. Odd and even harmonics up to the 15th order, as well as Compton peaks which were produced by the high harmonics in the spectrum, could been measured. These additional contributions can have a tremendous influence on the performance of the polarimeter and have to be taken into account for further polarimeter designs 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 4 |a Compton scattering 
650 4 |a X-ray diffraction 
650 4 |a monochromator 
650 4 |a polarimetry 
650 4 |a undulator high harmonics 
700 1 |a Schulze, Kai S  |e verfasserin  |4 aut 
700 1 |a Uschmann, Ingo  |e verfasserin  |4 aut 
700 1 |a Kämpfer, Tino  |e verfasserin  |4 aut 
700 1 |a Weber, Günter  |e verfasserin  |4 aut 
700 1 |a Hahn, Christoph  |e verfasserin  |4 aut 
700 1 |a Wille, Hans Christian  |e verfasserin  |4 aut 
700 1 |a Schlage, Kai  |e verfasserin  |4 aut 
700 1 |a Röhlsberger, Ralf  |e verfasserin  |4 aut 
700 1 |a Förster, Eckhart  |e verfasserin  |4 aut 
700 1 |a Stöhlker, Thomas  |e verfasserin  |4 aut 
700 1 |a Paulus, Gerhard G  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 22(2015), 5 vom: 20. Sept., Seite 1151-4  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:22  |g year:2015  |g number:5  |g day:20  |g month:09  |g pages:1151-4 
856 4 0 |u http://dx.doi.org/10.1107/S1600577515011510  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 22  |j 2015  |e 5  |b 20  |c 09  |h 1151-4