Multi-frame elastography using a handheld force-controlled ultrasound probe

We propose a new method for strain field estimation in quasi-static ultrasound elastography based on matching RF data frames of compressed tissues. The method benefits from using a handheld force-controlled ultrasound probe, which provides the contact force magnitude and therefore improves repeatabi...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 62(2015), 8 vom: 16. Aug., Seite 1486-500
1. Verfasser: Kuzmin, Andrey (VerfasserIn)
Weitere Verfasser: Zakrzewski, Aaron M, Anthony, Brian W, Lempitsky, Victor
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2015
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article
Beschreibung
Zusammenfassung:We propose a new method for strain field estimation in quasi-static ultrasound elastography based on matching RF data frames of compressed tissues. The method benefits from using a handheld force-controlled ultrasound probe, which provides the contact force magnitude and therefore improves repeatability of displacement field estimation. The displacement field is estimated in a two-phase manner using triplets of RF data frames consisting of a pre-compression image and two post-compression images obtained with lower and higher compression ratios. First, a reliable displacement field estimate is calculated for the first post-compression frame. Second, we use this displacement estimate to warp the second post-compression frame while using linear elasticity to obtain an initial approximation. Final displacement estimation is refined using the warped image. The two-phase displacement estimation allows for higher compression ratios, thus increasing the practical resolution of the strain estimates. The strain field is computed from a displacement field using a smoothness- regularized energy functional, which takes into consideration local displacement estimation quality. The minimization is performed using an efficient primal-dual hybrid gradient algorithm, which can leverage the architecture of a graphical processing unit. The method is quantitatively evaluated using finite element simulations. We compute strain estimates for tissue-mimicking phantoms with known elastic properties and finally perform a qualitative validation using in vivo patient data
Beschreibung:Date Completed 12.05.2016
Date Revised 25.11.2016
published: Print
Citation Status MEDLINE
ISSN:1525-8955
DOI:10.1109/TUFFC.2015.007133