Multi-frame elastography using a handheld force-controlled ultrasound probe
We propose a new method for strain field estimation in quasi-static ultrasound elastography based on matching RF data frames of compressed tissues. The method benefits from using a handheld force-controlled ultrasound probe, which provides the contact force magnitude and therefore improves repeatabi...
Veröffentlicht in: | IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 62(2015), 8 vom: 16. Aug., Seite 1486-500 |
---|---|
1. Verfasser: | |
Weitere Verfasser: | , , |
Format: | Online-Aufsatz |
Sprache: | English |
Veröffentlicht: |
2015
|
Zugriff auf das übergeordnete Werk: | IEEE transactions on ultrasonics, ferroelectrics, and frequency control |
Schlagworte: | Journal Article |
Zusammenfassung: | We propose a new method for strain field estimation in quasi-static ultrasound elastography based on matching RF data frames of compressed tissues. The method benefits from using a handheld force-controlled ultrasound probe, which provides the contact force magnitude and therefore improves repeatability of displacement field estimation. The displacement field is estimated in a two-phase manner using triplets of RF data frames consisting of a pre-compression image and two post-compression images obtained with lower and higher compression ratios. First, a reliable displacement field estimate is calculated for the first post-compression frame. Second, we use this displacement estimate to warp the second post-compression frame while using linear elasticity to obtain an initial approximation. Final displacement estimation is refined using the warped image. The two-phase displacement estimation allows for higher compression ratios, thus increasing the practical resolution of the strain estimates. The strain field is computed from a displacement field using a smoothness- regularized energy functional, which takes into consideration local displacement estimation quality. The minimization is performed using an efficient primal-dual hybrid gradient algorithm, which can leverage the architecture of a graphical processing unit. The method is quantitatively evaluated using finite element simulations. We compute strain estimates for tissue-mimicking phantoms with known elastic properties and finally perform a qualitative validation using in vivo patient data |
---|---|
Beschreibung: | Date Completed 12.05.2016 Date Revised 25.11.2016 published: Print Citation Status MEDLINE |
ISSN: | 1525-8955 |
DOI: | 10.1109/TUFFC.2015.007133 |