Picosecond-resolved X-ray absorption spectroscopy at low signal contrast using a hard X-ray streak camera

A picosecond-resolving hard-X-ray streak camera has been in operation for several years at Sector 7 of the Advanced Photon Source (APS). Several upgrades have been implemented over the past few years to optimize integration into the beamline, reduce the timing jitter, and improve the signal-to-noise...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 22(2015), 4 vom: 02. Juli, Seite 1022-9
1. Verfasser: Adams, Bernhard W (VerfasserIn)
Weitere Verfasser: Rose-Petruck, Christoph, Jiao, Yishuo
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2015
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Research Support, U.S. Gov't, Non-P.H.S. X-ray streak camera high repetition rate photochemistry ultrafast laser
LEADER 01000naa a22002652 4500
001 NLM250511851
003 DE-627
005 20231224155948.0
007 cr uuu---uuuuu
008 231224s2015 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577515007912  |2 doi 
028 5 2 |a pubmed24n0835.xml 
035 |a (DE-627)NLM250511851 
035 |a (NLM)26134806 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Adams, Bernhard W  |e verfasserin  |4 aut 
245 1 0 |a Picosecond-resolved X-ray absorption spectroscopy at low signal contrast using a hard X-ray streak camera 
264 1 |c 2015 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 18.09.2015 
500 |a Date Revised 03.07.2015 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a A picosecond-resolving hard-X-ray streak camera has been in operation for several years at Sector 7 of the Advanced Photon Source (APS). Several upgrades have been implemented over the past few years to optimize integration into the beamline, reduce the timing jitter, and improve the signal-to-noise ratio. These include the development of X-ray optics for focusing the X-rays into the sample and the entrance slit of the streak camera, and measures to minimize the amount of laser light needed to generate the deflection-voltage ramp. For the latter, the photoconductive switch generating the deflection ramp was replaced with microwave power electronics. With these, the streak camera operates routinely at 88 MHz repetition rate, thus making it compatible with all of the APS fill patterns including use of all the X-rays in the 324-bunch mode. Sample data are shown to demonstrate the performance 
650 4 |a Journal Article 
650 4 |a Research Support, U.S. Gov't, Non-P.H.S. 
650 4 |a X-ray streak camera 
650 4 |a high repetition rate 
650 4 |a photochemistry 
650 4 |a ultrafast laser 
700 1 |a Rose-Petruck, Christoph  |e verfasserin  |4 aut 
700 1 |a Jiao, Yishuo  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 22(2015), 4 vom: 02. Juli, Seite 1022-9  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:22  |g year:2015  |g number:4  |g day:02  |g month:07  |g pages:1022-9 
856 4 0 |u http://dx.doi.org/10.1107/S1600577515007912  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 