Standardless multicomponent qNMR analysis of compounds with overlapped resonances based on the combination of ICA and PULCON

Copyright © 2015 John Wiley & Sons, Ltd.

Bibliographische Detailangaben
Veröffentlicht in:Magnetic resonance in chemistry : MRC. - 1985. - 53(2015), 10 vom: 17. Okt., Seite 821-8
1. Verfasser: Monakhova, Yulia B (VerfasserIn)
Weitere Verfasser: Lachenmeier, Dirk W, Kuballa, Thomas, Mushtakova, Svetlana P
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2015
Zugriff auf das übergeordnete Werk:Magnetic resonance in chemistry : MRC
Schlagworte:Journal Article 1H NMR PILCON principle fruit juice independent component analysis standardless analysis
LEADER 01000naa a22002652 4500
001 NLM250491524
003 DE-627
005 20231224155910.0
007 cr uuu---uuuuu
008 231224s2015 xx |||||o 00| ||eng c
024 7 |a 10.1002/mrc.4275  |2 doi 
028 5 2 |a pubmed24n0835.xml 
035 |a (DE-627)NLM250491524 
035 |a (NLM)26132651 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Monakhova, Yulia B  |e verfasserin  |4 aut 
245 1 0 |a Standardless multicomponent qNMR analysis of compounds with overlapped resonances based on the combination of ICA and PULCON 
264 1 |c 2015 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 14.12.2015 
500 |a Date Revised 19.09.2015 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Copyright © 2015 John Wiley & Sons, Ltd. 
520 |a A fast and reliable nuclear magnetic resonance (NMR) method for quantitative analysis of targeted compounds with overlapped signals in complex mixtures has been established. The method is based on the combination of chemometric treatment for spectra deconvolution and the PULCON principle (pulse length based concentration determination) for quantification. Independent component analysis (ICA) (mutual information least dependent component analysis (MILCA) algorithm) was applied for spectra deconvolution in up to six component mixtures with known composition. The resolved matrices (independent components, ICs and ICA scores) were used for identification of analytes, calculating their relative concentrations and absolute integral intensity of selected resonances. The absolute analyte concentrations in multicomponent mixtures and authentic samples were then calculated using the PULCON principle. Instead of conventional application of absolute integral intensity in case of undisturbed signals, the multiplication of resolved IC absolute integral and its relative concentration in the mixture for each component was used. Correction factors that are required for quantification and are unique for each analyte were also estimated. The proposed method was applied for analysis of up to five components in lemon and orange juice samples with recoveries between 90% and 111%. The total duration of analysis is approximately 45 min including measurements, spectra decomposition and quantification. The results demonstrated that the proposed method is a promising tool for rapid simultaneous quantification of up to six components in case of spectral overlap and the absence of reference materials 
650 4 |a Journal Article 
650 4 |a 1H NMR 
650 4 |a PILCON principle 
650 4 |a fruit juice 
650 4 |a independent component analysis 
650 4 |a standardless analysis 
700 1 |a Lachenmeier, Dirk W  |e verfasserin  |4 aut 
700 1 |a Kuballa, Thomas  |e verfasserin  |4 aut 
700 1 |a Mushtakova, Svetlana P  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Magnetic resonance in chemistry : MRC  |d 1985  |g 53(2015), 10 vom: 17. Okt., Seite 821-8  |w (DE-627)NLM098179667  |x 1097-458X  |7 nnns 
773 1 8 |g volume:53  |g year:2015  |g number:10  |g day:17  |g month:10  |g pages:821-8 
856 4 0 |u http://dx.doi.org/10.1002/mrc.4275  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 53  |j 2015  |e 10  |b 17  |c 10  |h 821-8