Retained Intraocular Perfluoro-n-octane After Valved Cannula Pars Plana Vitrectomy for Retinal Detachment

Copyright 2015, SLACK Incorporated.

Bibliographische Detailangaben
Veröffentlicht in:Ophthalmic surgery, lasers & imaging retina. - 2013. - 46(2015), 4 vom: 13. Apr., Seite 451-6
1. Verfasser: Oellers, Patrick (VerfasserIn)
Weitere Verfasser: Schneider, Eric W, Fekrat, Sharon, Mahmoud, Tamer H, Mruthyunjaya, Prithvi, Hahn, Paul
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2015
Zugriff auf das übergeordnete Werk:Ophthalmic surgery, lasers & imaging retina
Schlagworte:Case Reports Journal Article Fluorocarbons perfluorooctane 6P60ZBK0QL
LEADER 01000naa a22002652 4500
001 NLM248980238
003 DE-627
005 20231224152600.0
007 cr uuu---uuuuu
008 231224s2015 xx |||||o 00| ||eng c
024 7 |a 10.3928/23258160-20150422-08  |2 doi 
028 5 2 |a pubmed24n0830.xml 
035 |a (DE-627)NLM248980238 
035 |a (NLM)25970866 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Oellers, Patrick  |e verfasserin  |4 aut 
245 1 0 |a Retained Intraocular Perfluoro-n-octane After Valved Cannula Pars Plana Vitrectomy for Retinal Detachment 
264 1 |c 2015 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 23.10.2015 
500 |a Date Revised 14.05.2015 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a Copyright 2015, SLACK Incorporated. 
520 |a BACKGROUND AND OBJECTIVE: To investigate cases of retained intraocular perfluoro-n-octane (PFO) after pars plana vitrectomy (PPV) for retinal detachment (RD) 
520 |a PATIENTS AND METHODS: Retrospective, noncomparative case series of six eyes with retained intraocular PFO after RD repair. Clinical data were supplemented with an experimental silicone eye model 
520 |a RESULTS: A cluster of six cases of retained intraocular PFO after PPV for RD repair were noted shortly after transitioning to valved cannulas. PFO was noted in the anterior chamber (AC) and/or vitreous and removed with AC paracentesis, AC wash-out, and/or PPV. A silicone eye model demonstrated that PFO levels are maintained anterior to cannula insertion with valved cannulas only 
520 |a CONCLUSION: The authors hypothesize that anterior PFO fill using valved cannulas can lead to sequestration within the AC, zonules, ciliary sulcus, ciliary teeth, and/or capsular bag. They suggest vigilance in not overfilling PFO, particularly when transitioning to use of valved cannulas, to minimize the risk of intraocular retention 
650 4 |a Case Reports 
650 4 |a Journal Article 
650 7 |a Fluorocarbons  |2 NLM 
650 7 |a perfluorooctane  |2 NLM 
650 7 |a 6P60ZBK0QL  |2 NLM 
700 1 |a Schneider, Eric W  |e verfasserin  |4 aut 
700 1 |a Fekrat, Sharon  |e verfasserin  |4 aut 
700 1 |a Mahmoud, Tamer H  |e verfasserin  |4 aut 
700 1 |a Mruthyunjaya, Prithvi  |e verfasserin  |4 aut 
700 1 |a Hahn, Paul  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Ophthalmic surgery, lasers & imaging retina  |d 2013  |g 46(2015), 4 vom: 13. Apr., Seite 451-6  |w (DE-627)NLM224956647  |x 2325-8179  |7 nnns 
773 1 8 |g volume:46  |g year:2015  |g number:4  |g day:13  |g month:04  |g pages:451-6 
856 4 0 |u http://dx.doi.org/10.3928/23258160-20150422-08  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_24 
912 |a GBV_ILN_31 
912 |a GBV_ILN_40 
912 |a GBV_ILN_63 
912 |a GBV_ILN_65 
912 |a GBV_ILN_69 
912 |a GBV_ILN_70 
912 |a GBV_ILN_90 
912 |a GBV_ILN_91 
912 |a GBV_ILN_130 
912 |a GBV_ILN_135 
912 |a GBV_ILN_136 
912 |a GBV_ILN_151 
912 |a GBV_ILN_181 
912 |a GBV_ILN_203 
912 |a GBV_ILN_217 
912 |a GBV_ILN_235 
912 |a GBV_ILN_289 
912 |a GBV_ILN_294 
912 |a GBV_ILN_297 
912 |a GBV_ILN_350 
912 |a GBV_ILN_352 
912 |a GBV_ILN_674 
912 |a GBV_ILN_676 
912 |a GBV_ILN_688 
912 |a GBV_ILN_698 
912 |a GBV_ILN_721 
912 |a GBV_ILN_737 
912 |a GBV_ILN_791 
912 |a GBV_ILN_812 
951 |a AR 
952 |d 46  |j 2015  |e 4  |b 13  |c 04  |h 451-6